Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Jul;140(1):73-9, 79.e1-2.
doi: 10.1016/j.jtcvs.2009.09.032. Epub 2009 Nov 26.

Long-term (5- to 20-year) patency of the radial artery for coronary bypass grafting

Affiliations
Free article

Long-term (5- to 20-year) patency of the radial artery for coronary bypass grafting

Paul Achouh et al. J Thorac Cardiovasc Surg. 2010 Jul.
Free article

Abstract

Objective: The aim of this study was to assess the angiographic results of the radial artery as a coronary bypass conduit at long term (>5 years).

Methods: Radial artery grafts were controlled in 202 patients at 10.1 years by conventional angiography (n = 79) and computed tomography (n = 123). Clinical or paraclinical evidence of ischemia was noted in 81 patients, whereas 121 patients were asymptomatic. Some 520 conduits were controlled: radial artery (n = 230), left internal thoracic artery (n = 190), right internal thoracic artery (n = 30), and veins (n = 70). Radial arteries were anastomosed to the right coronary (24%), marginal (58%), diagonal (16%), and left anterior descending (<1%) arteries, whereas left internal thoracic arteries were primarily anastomosed to the left anterior descending artery (95%). The mean number of antithrombotic and anti-anginal medications was 1.2 and 1.9 per patient, respectively.

Results: The ejection fraction was slightly decreased compared with its preoperative value (54% +/- 11% vs 57% +/- 9%; P = .009). Nine reoperations were required at 10.5 years for valve replacement (n = 8) and isolated bypass (n = 1). Percutaneous intervention was performed in 48 patients (24%) at 7.6 years on a graft (28%) or a native coronary artery (72%). The 10-year patency of radial artery grafts was 83%, which was lower than the patency of left internal thoracic arteries (95%, P < .001) and similar to the patency of right internal thoracic arteries (87%, P = .66) and veins (81%, P = .50). No medication seemed to influence radial artery graft patency (aspirin: P = .26; calcium blockers: P = .36). All graft patency was lower when clinical or paraclinical evidence of ischemia was present than in asymptomatic cases (83% vs 90% P = .02). The patency of left anterior descending grafts was higher than that of non-left anterior descending grafts (96% vs 82% P < .001).

Conclusion: The radial artery-to-coronary bypass conduit provided a low coronary reoperation rate with an excellent patency (83%) up to 20 years postoperatively.

PubMed Disclaimer

MeSH terms

Substances

LinkOut - more resources