Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Apr;23(4):229-41.
doi: 10.1093/protein/gzp074. Epub 2009 Nov 27.

Knowledge-based design of reagentless fluorescent biosensors from a designed ankyrin repeat protein

Affiliations
Free article

Knowledge-based design of reagentless fluorescent biosensors from a designed ankyrin repeat protein

Elodie Brient-Litzler et al. Protein Eng Des Sel. 2010 Apr.
Free article

Abstract

Designed ankyrin repeat proteins (DARPins) can be selected from combinatorial libraries to bind any target antigen. They show high levels of recombinant expression, solubility and stability, and contain no cysteine residue. The possibility of obtaining, from any DARPin and at high yields, fluorescent conjugates which respond to the binding of the antigen by a variation of fluorescence, would have numerous applications in micro- and nano-analytical sciences. This possibility was explored with Off7, a DARPin directed against the maltose binding protein (MalE) from Escherichia coli, with known crystal structure of the complex. Eight residues of Off7, whose solvent accessible surface area varies on association with the antigen but which are not in direct contact with the antigen, were individually mutated into cysteine and then chemically coupled with a fluorophore. The conjugates were ranked according to their relative sensitivities. All of them showed an increase in their fluorescence intensity on antigen binding by >1.7-fold. The best conjugate retained the same affinity as the parental DARPin. Its signal increased linearly and specifically with the concentration of antigen, up to 15-fold in buffer and 3-fold in serum when fully saturated, the difference being mainly due to the absorption of light by serum. Its lower limit of detection was equal to 0.3 nM with a standard spectrofluorometer. Titrations with potassium iodide indicated that the fluorescence variation was due to a shielding of the fluorescent group from the solvent by the antigen. These results suggest rules for the design of reagentless fluorescent biosensors from any DARPin.

PubMed Disclaimer

Publication types