Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Mar;26(3):309-21.
doi: 10.1007/s10554-009-9544-0. Epub 2009 Nov 28.

Comparison of 3D-diffusion-prepared segmented steady-state free precession and 2D fast spin echo imaging of femoral artery atherosclerosis

Affiliations
Comparative Study

Comparison of 3D-diffusion-prepared segmented steady-state free precession and 2D fast spin echo imaging of femoral artery atherosclerosis

Katsumi Hayashi et al. Int J Cardiovasc Imaging. 2010 Mar.

Abstract

Magnetic resonance (MR) imaging is a promising modality for the in vivo detection and characterization of atherosclerotic lesions in peripheral arteries. 2D imaging techniques for evaluation of peripheral artery disease (PAD) suffer from poor spatial coverage and have long scan times. The purpose of this study was to compare a diffusion prepared dark blood 3D steady state free precession (3D-DP-SSFP) sequence for evaluating atherosclerotic plaque burden in inguinal and thigh segments of the femoral artery and comparing the results obtained with 2D turbo spin echo (2D-TSE) techniques. A further goal of the study was to examine the inter observer reproducibility of MR plaque burden measures using the 3D DP-SSFP technique. Results of the study indicated higher signal to noise ratios for the 3D-DP-SSFP technique and higher CNR (better vessel-wall delineation) compared to the 2D-TSE technique. Furthermore, a good correlation between 3D-DP-SSFP and 2D-TSE techniques for the inguinal segment but poorer correlation for the thigh segment was observed. Inter-observer reproducibility for the 3D plaque burden measures was excellent. 3D-DP-SSFP may be a useful and reproducible technique for evaluating atherosclerosis in peripheral arteries.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Biopharm Stat. 2007;17(4):571-82 - PubMed
    1. Invest Radiol. 2009 Sep;44(9):619-26 - PubMed
    1. Circulation. 2000 Aug 1;102(5):506-10 - PubMed
    1. Circulation. 2004 Aug 31;110(9):1156-61 - PubMed
    1. J Magn Reson Imaging. 2005 Nov;22(5):628-33 - PubMed

Publication types

LinkOut - more resources