Alternative user interface devices for improved navigation of CT datasets
- PMID: 19949832
- PMCID: PMC3046793
- DOI: 10.1007/s10278-009-9252-2
Alternative user interface devices for improved navigation of CT datasets
Abstract
The workflow in radiology departments has changed dramatically with the transition to digital PACS, especially with the shift from tile mode to stack mode display of volumetric images. With the increasing number of images in routinely captured datasets, the standard user interface devices (UIDs) become inadequate. One basic approach to improve the navigation of the stack mode datasets is to take advantage of alternative UIDs developed for other domains, such as the computer game industry. We evaluated three UIDs both in clinical practice and in a task-based experiment. After using the devices in the daily image interpretation work, the readers reported that both of the tested alternative UIDs were better in terms of ergonomics compared to the standard mouse and that both alternatives were more efficient when reviewing large CT datasets. In the task-based experiment, one of the tested devices was faster than the standard mouse, while the other alternative was not significantly faster. One of the tested alternative devices showed a larger number of traversed images during the task. The results indicate that alternative user interface devices can improve the navigation of stack mode datasets and that radiologists should consider the potential benefits of alternatives to the standard mouse.
Figures

Similar articles
-
Optimizing analysis, visualization, and navigation of large image data sets: one 5000-section CT scan can ruin your whole day.Radiology. 2011 May;259(2):346-62. doi: 10.1148/radiol.11091276. Radiology. 2011. PMID: 21502391 Free PMC article. Review.
-
Alternative PACS interface devices are well-accepted and may reduce radiologist's musculoskeletal discomfort as compared to keyboard-mouse-recording device.Eur Radiol. 2020 Sep;30(9):5200-5208. doi: 10.1007/s00330-020-06851-4. Epub 2020 Apr 25. Eur Radiol. 2020. PMID: 32333147
-
Radiologist assessment of PACS user interface devices.J Am Coll Radiol. 2006 Apr;3(4):265-73. doi: 10.1016/j.jacr.2005.10.016. J Am Coll Radiol. 2006. PMID: 17412058
-
Interpretation of CT scans with PACS image display in stack mode.Radiology. 1997 Apr;203(1):207-9. doi: 10.1148/radiology.203.1.9122394. Radiology. 1997. PMID: 9122394
-
Learning from Gamers: Integrating Alternative Input Devices and AutoHotkey Scripts to Simplify Repetitive Tasks and Improve Workflow.Radiographics. 2020 Jan-Feb;40(1):141-150. doi: 10.1148/rg.2020190077. Radiographics. 2020. PMID: 31917658 Review.
Cited by
-
Factors Affecting Radiologist's PACS Usage.J Digit Imaging. 2016 Dec;29(6):670-676. doi: 10.1007/s10278-016-9881-1. J Digit Imaging. 2016. PMID: 27099222 Free PMC article.
-
Clinical evaluation of semi-automatic landmark-based lesion tracking software for CT-scans.Cancer Imaging. 2014 Apr 22;14(1):6. doi: 10.1186/1470-7330-14-6. Cancer Imaging. 2014. PMID: 25609496 Free PMC article.
-
Of Mice and Roentgen: Radiologist Satisfaction with a Non-conventional 13-Button Mouse-One Institution's Experience.J Digit Imaging. 2018 Dec;31(6):776-782. doi: 10.1007/s10278-018-0094-7. J Digit Imaging. 2018. PMID: 29869010 Free PMC article.
-
Optimizing analysis, visualization, and navigation of large image data sets: one 5000-section CT scan can ruin your whole day.Radiology. 2011 May;259(2):346-62. doi: 10.1148/radiol.11091276. Radiology. 2011. PMID: 21502391 Free PMC article. Review.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical