Whole-body magnetic resonance angiography with additional steady-state acquisition of the infragenicular arteries in patients with peripheral arterial disease
- PMID: 19957180
- DOI: 10.1007/s00270-009-9759-4
Whole-body magnetic resonance angiography with additional steady-state acquisition of the infragenicular arteries in patients with peripheral arterial disease
Abstract
The purpose of this investigation was to determine if addition of infragenicular steady-state (SS) magnetic resonance angiography (MRA) to first-pass imaging improves diagnostic performance compared with first-pass imaging alone in patients with peripheral arterial disease (PAD) undergoing whole-body (WB) MRA. Twenty consecutive patients with PAD referred to digital-subtraction angiography (DSA) underwent WB-MRA. Using a bolus-chase technique, first-pass WB-MRA was performed from the supra-aortic vessels to the ankles. The blood-pool contrast agent gadofosveset trisodium was used at a dose of 0.03 mmol/kg body weight. Ten minutes after injection of the contrast agent, high-resolution (0.7-mm isotropic voxels) SS-MRA of the infragenicular arteries was performed. Using DSA as the "gold standard," sensitivities and specificities for detecting significant arterial stenoses (>/=50% luminal narrowing) with first-pass WB-MRA, SS-MRA, and combined first-pass and SS-MRA were calculated. Kappa statistics were used to determine intermodality agreement between MRA and DSA. Overall sensitivity and specificity for detecting significant arterial stenoses with first-pass WB-MRA was 0.70 (95% confidence interval 0.61 to 0.78) and 0.97 (0.94 to 0.99), respectively. In first-pass WB-MRA, the lowest sensitivity was in the infragenicular region, with a value of 0.42 (0.23 to 0.63). Combined analysis of first-pass WB-MRA and SS-MRA increased sensitivity to 0.81 (0.60 to 0.93) in the infragenicular region, with specificity of 0.94 (0.88 to 0.97). Sensitivity and specificity for detecting significant arterial stenoses with isolated infragenicular SS-MRA was 0.47 (0.27 to 0.69) and 0.86 (0.78 to 0.91), respectively. Intermodality agreement between MRA and DSA in the infragenicular region was moderate for first-pass WB-MRA (kappa = 0.49), fair for SS-MRA (kappa = 0.31), and good for combined first-pass/SS-MRA (kappa = 0.71). Addition of infragenicular SS-MRA to first-pass WB MRA improves diagnostic performance.
Similar articles
-
Whole-body MR angiography in patients with peripheral arterial disease.Dan Med Bull. 2010 Dec;57(12):B4231. Dan Med Bull. 2010. PMID: 21122468 Review.
-
Whole-body MR angiography with body coil acquisition at 3 T in patients with peripheral arterial disease using the contrast agent gadofosveset trisodium.Acad Radiol. 2009 Jun;16(6):654-61. doi: 10.1016/j.acra.2008.12.018. Epub 2009 Mar 17. Acad Radiol. 2009. PMID: 19297207
-
Whole-body magnetic resonance angiography at 3 tesla using a hybrid protocol in patients with peripheral arterial disease.Cardiovasc Intervent Radiol. 2009 Sep;32(5):877-86. doi: 10.1007/s00270-009-9549-z. Epub 2009 Mar 19. Cardiovasc Intervent Radiol. 2009. PMID: 19296155
-
High-resolution steady state magnetic resonance angiography of the carotid arteries: are intravascular agents necessary?: feasibility and preliminary experience with gadobenate dimeglumine.Invest Radiol. 2009 Dec;44(12):784-92. doi: 10.1097/RLI.0b013e3181bfe38a. Invest Radiol. 2009. PMID: 19858728
-
Contrast-enhanced peripheral MRA: technique and contrast agents.Acta Radiol. 2012 Sep 1;53(7):769-77. doi: 10.1258/ar.2012.120008. Epub 2012 Jul 28. Acta Radiol. 2012. PMID: 22843836 Review.
Cited by
-
A comparison between gadofosveset trisodium and gadobenate dimeglumine for steady state MRA of the thoracic vasculature.Biomed Res Int. 2014;2014:625614. doi: 10.1155/2014/625614. Epub 2014 Jun 29. Biomed Res Int. 2014. PMID: 25061611 Free PMC article. Clinical Trial.
-
Three-station three-dimensional bolus-chase MR angiography with real-time fluoroscopic tracking.Radiology. 2014 Jul;272(1):241-51. doi: 10.1148/radiol.14131603. Epub 2014 Mar 14. Radiology. 2014. PMID: 24635676 Free PMC article.
-
Improved detection of in-stent restenosis by blood pool agent-enhanced, high-resolution, steady-state magnetic resonance angiography.Eur Radiol. 2011 Oct;21(10):2158-65. doi: 10.1007/s00330-011-2145-z. Epub 2011 May 10. Eur Radiol. 2011. PMID: 21556908
-
ECG-triggered non-contrast-enhanced MR angiography (TRANCE) versus digital subtraction angiography (DSA) in patients with peripheral arterial occlusive disease of the lower extremities.Eur Radiol. 2011 Sep;21(9):1979-87. doi: 10.1007/s00330-011-2132-4. Epub 2011 May 1. Eur Radiol. 2011. PMID: 21533632
-
String-like lumen in below-the-knee chronic total occlusions on contrast-enhanced magnetic resonance angiography predicts intraluminal recanalization and better blood flow restoration.Eur Radiol. 2017 Jul;27(7):2835-2842. doi: 10.1007/s00330-016-4647-1. Epub 2016 Oct 30. Eur Radiol. 2017. PMID: 27796479
MeSH terms
Substances
LinkOut - more resources
Full Text Sources