Evaluation of the centreing ability of the ProTaper Universal rotary system in curved roots in comparison to Nitiflex files
- PMID: 19961458
- DOI: 10.1111/j.1747-4477.2009.00168.x
Evaluation of the centreing ability of the ProTaper Universal rotary system in curved roots in comparison to Nitiflex files
Abstract
The aim of the present study was to assess the centreing ability of the ProTaper Universal rotary system in curved roots in comparison to Nitiflex files, by means of preoperative and postoperative imaging of a cross-section of the apical third. Twenty mesiobuccal canals of human first mandibular molars with a degree of curvature ranging from 35 degrees to 60 degrees were divided into two groups of 10 specimens each: group 1, ProTaper Universal rotary system; group 2 (control), Nitiflex files. All instruments produced morphological alterations. The Student's t-test and Kruskal-Wallis test showed that the differences were not statistically significant, except for the specimens instrumented by Nitiflex file #30. The ProTaper Universal showed the capacity for producing centered preparations in curved and thin root canals with low proportions of apical deviation.
Similar articles
-
Comparison of the centring ability of the ProTaper™ and ProTaper Universal™ rotary systems for preparing curved root canals.Aust Endod J. 2013 Apr;39(1):25-30. doi: 10.1111/j.1747-4477.2010.00276.x. Epub 2010 Oct 24. Aust Endod J. 2013. PMID: 23551510 Clinical Trial.
-
Instrument separation analysis of multi-used ProTaper Universal rotary system during root canal therapy.J Endod. 2011 Jun;37(6):758-63. doi: 10.1016/j.joen.2011.02.021. Epub 2011 Apr 2. J Endod. 2011. PMID: 21787484
-
Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus RaCe. Part 2. Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth.Int Endod J. 2004 Apr;37(4):239-48. doi: 10.1111/j.0143-2885.2004.00783.x. Int Endod J. 2004. PMID: 15056350
-
Root canal shaping using rotary nickel-titanium files in preclinical dental education in Turkey.J Dent Educ. 2012 Apr;76(4):509-13. J Dent Educ. 2012. PMID: 22473564
-
Nickel-titanium rotary systems: review of existing instruments and geometries.Dent Today. 2000 Oct;19(10):86-8, 90-5. Dent Today. 2000. PMID: 12524811 Review. No abstract available.
Cited by
-
Evaluation of Microbial Reduction in Root Canals Instrumented with Reciprocating and Rotary Systems.Acta Stomatol Croat. 2015 Dec;49(4):294-303. doi: 10.15644/asc49/4/4. Acta Stomatol Croat. 2015. PMID: 27688413 Free PMC article.
-
Evaluation of Effect of Irrigants with or without Surfactant on Root Canal Transportation by Cone Beam Computed Tomography-An In vitro Study.J Clin Diagn Res. 2017 Sep;11(9):ZC75-ZC78. doi: 10.7860/JCDR/2017/27258.10677. Epub 2017 Sep 1. J Clin Diagn Res. 2017. PMID: 29207839 Free PMC article.
-
Assessment of the Centralization of Root Canal Preparation with Rotary Systems.Acta Stomatol Croat. 2016 Sep;50(3):242-250. doi: 10.15644/asc50/3/7. Acta Stomatol Croat. 2016. PMID: 27847398 Free PMC article.
-
Detection of Procedural Errors with Stainless Steel and NiTi Instruments by Undergraduate Students Using Conventional Radiograph and Cone Beam Computed Tomography.Iran Endod J. 2013 Fall;8(4):160-5. Epub 2013 Oct 7. Iran Endod J. 2013. PMID: 24171022 Free PMC article.
-
Assessment of canal walls after biomechanical preparation of root canals instrumented with Protaper Universal rotary system.J Appl Oral Sci. 2009 Nov-Dec;17(6):590-5. doi: 10.1590/s1678-77572009000600010. J Appl Oral Sci. 2009. PMID: 20027432 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources