Reducing scalpel injuries in the operating room
- PMID: 19961972
- DOI: 10.1016/j.aorn.2009.07.025
Reducing scalpel injuries in the operating room
Abstract
Scalpel injuries can expose surgeons, nurses, and other OR personnel to bloodborne pathogens. Direct and indirect costs of managing exposure include time spent reporting, treating, and following up on the injuries; salaries and benefits for injured staff members; laboratory testing of exposure sources and exposed personnel; and postexposure prophylaxis. Standard precautions, training and awareness for those at risk, the use of neutral passing zones, and safety-engineered devices have helped decrease the incidence of injury for specific categories of sharps. One new safety device is a hand piece that uses electrosurgical plasma induced with pulsed radio-frequency energy to cut tissue.
(c) AORN, Inc, 2009.
Similar articles
-
Slash sharps risk for surgical personnel.Nurs Manage. 2005 Nov;Suppl:28-9. Nurs Manage. 2005. PMID: 16353418 No abstract available.
-
Reducing the risks of sharps injuries in health professionals.Nurs Times. 2004 Jun 29-Jul 6;100(26):28-9. Nurs Times. 2004. PMID: 15318686 Review.
-
Controlling infection potentials when passing surgical instruments.Todays OR Nurse. 1993 Nov-Dec;15(6):35-8. Todays OR Nurse. 1993. PMID: 8291075
-
Occupational blood exposure among unlicensed home care workers and home care registered nurses: are they protected?Am J Ind Med. 2009 Jul;52(7):563-70. doi: 10.1002/ajim.20701. Am J Ind Med. 2009. PMID: 19479817
-
Reducing exposure risk in the operating room.Prairie Rose. 2008 May-Jul;77(2):10-3. Prairie Rose. 2008. PMID: 18593076 Review.
Cited by
-
An electrical plasma dissection tool for surgical treatment of chronic ulcers: Results of a prospective randomised trial.Int Wound J. 2018 Oct;15(5):717-721. doi: 10.1111/iwj.12915. Epub 2018 Mar 30. Int Wound J. 2018. PMID: 29600828 Free PMC article.
-
Prevalence of needlestick injury among healthcare workers in Ethiopia: a systematic review and meta-analysis.Environ Health Prev Med. 2019 Aug 14;24(1):52. doi: 10.1186/s12199-019-0807-7. Environ Health Prev Med. 2019. PMID: 31409284 Free PMC article.
-
Sharps injuries: the risks and relevance to plastic surgeons.Plast Reconstr Surg. 2013 Apr;131(4):784-791. doi: 10.1097/PRS.0b013e3182818bae. Plast Reconstr Surg. 2013. PMID: 23542251 Free PMC article.
-
Electrocautery Devices With Feedback Mode and Teflon-Coated Blades Create Less Surgical Smoke for a Quality Improvement in the Operating Theater.Medicine (Baltimore). 2015 Jul;94(27):e1104. doi: 10.1097/MD.0000000000001104. Medicine (Baltimore). 2015. PMID: 26166102 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical