Ultra-low-power wearable biopotential sensor nodes
- PMID: 19964056
- DOI: 10.1109/IEMBS.2009.5333154
Ultra-low-power wearable biopotential sensor nodes
Abstract
This paper discusses ultra-low-power wireless sensor nodes intended for wearable biopotential monitoring. Specific attention is given to mixed-signal design approaches and their impact on the overall system power dissipation. Examples of trade-offs in power dissipation between analog front-ends and digital signal processing are also given. It is shown how signal filtering can further reduce the internal power consumption of a node. Such power saving approaches are indispensable as real-life tests of custom wireless ECG patches reveal the need for artifact detection and correction. The power consumption of such additional features has to come from power savings elsewhere in the system as the overall power budget cannot increase.
Similar articles
-
Low energy wearable body-sensor-network.Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:3209-12. doi: 10.1109/IEMBS.2009.5333156. Annu Int Conf IEEE Eng Med Biol Soc. 2009. PMID: 19964057
-
Wireless powering and data telemetry for biomedical implants.Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:3221-4. doi: 10.1109/IEMBS.2009.5333163. Annu Int Conf IEEE Eng Med Biol Soc. 2009. PMID: 19964060
-
Miniaturization of implantable wireless power receiver.Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:3217-20. doi: 10.1109/IEMBS.2009.5333162. Annu Int Conf IEEE Eng Med Biol Soc. 2009. PMID: 19964059
-
A study of MAC protocols for WBANs.Sensors (Basel). 2010;10(1):128-45. doi: 10.3390/s100100128. Epub 2009 Dec 28. Sensors (Basel). 2010. PMID: 22315531 Free PMC article. Review.
-
Convergence Revolution Comes to Wearables: Multiple Advances are Taking Biosensor Networks to the Next Level in Health Care.IEEE Pulse. 2016 Jan-Feb;7(1):13-7. doi: 10.1109/MPUL.2015.2498475. IEEE Pulse. 2016. PMID: 26799721 Review.
Cited by
-
Body Area Networks for ubiquitous healthcare applications: opportunities and challenges.J Med Syst. 2011 Oct;35(5):1245-54. doi: 10.1007/s10916-011-9661-x. Epub 2011 Feb 17. J Med Syst. 2011. PMID: 21327950
-
Tablet-Based Wearable Patch Sensor Design for Continuous Cardiovascular System Monitoring in Postoperative Settings.Biosensors (Basel). 2023 Jun 4;13(6):615. doi: 10.3390/bios13060615. Biosensors (Basel). 2023. PMID: 37366980 Free PMC article.
-
A Digital Compressed Sensing-Based Energy-Efficient Single-Spot Bluetooth ECG Node.J Healthc Eng. 2018 Jan 11;2018:2687389. doi: 10.1155/2018/2687389. eCollection 2018. J Healthc Eng. 2018. PMID: 29599945 Free PMC article.
-
Wavelet-based Encoding Scheme for Controlling Size of Compressed ECG Segments in Telecardiology Systems.J Med Syst. 2017 Sep 12;41(10):166. doi: 10.1007/s10916-017-0817-1. J Med Syst. 2017. PMID: 28900815
MeSH terms
LinkOut - more resources
Other Literature Sources