Cardiac source localization by means of a single moving dipole solution during endocardial pacing in an animal model
- PMID: 19964556
- DOI: 10.1109/IEMBS.2009.5334014
Cardiac source localization by means of a single moving dipole solution during endocardial pacing in an animal model
Abstract
The accuracy of localizing the initiation site of cardiac activation by noninvasively estimating a single moving dipole (SMD) was investigated in a swine model. Body surface potential mapping (BSPM) and intracavitary noncontact mapping (NCM) were performed simultaneously during acute left ventricular (LV) endocardial pacing. For each animal, the boundary element model was constructed from preoperative magnetic resonance images (MRI). In each pacing study, the initiation site was localized by inversely estimating the location of an SMD from BSPM data. The results were compared with the precise pacing sites recorded by the NCM system. In total, four pacing sites from two pigs were analyzed, and the averaged source localization error was 16.8 +/- 2.3 mm. The present results indicate the potential of localizing focal cardiac events by estimating single moving dipole.
Similar articles
-
Equivalent moving dipole localization of cardiac ectopic activity in a swine model during pacing.IEEE Trans Inf Technol Biomed. 2010 Nov;14(6):1318-26. doi: 10.1109/TITB.2010.2051448. Epub 2010 May 27. IEEE Trans Inf Technol Biomed. 2010. PMID: 20515710 Free PMC article.
-
Noninvasive mapping of transmural potentials during activation in swine hearts from body surface electrocardiograms.IEEE Trans Med Imaging. 2012 Sep;31(9):1777-85. doi: 10.1109/TMI.2012.2202914. Epub 2012 Jun 6. IEEE Trans Med Imaging. 2012. PMID: 22692900 Free PMC article.
-
Estimation of global ventricular activation sequences by noninvasive three-dimensional electrical imaging: validation studies in a Swine model during pacing.J Cardiovasc Electrophysiol. 2008 May;19(5):535-40. doi: 10.1111/j.1540-8167.2007.01066.x. Epub 2007 Dec 20. J Cardiovasc Electrophysiol. 2008. PMID: 18179521 Free PMC article.
-
Localization of endocardial ectopic activity by means of noninvasive endocardial surface current density reconstruction.Phys Med Biol. 2011 Jul 7;56(13):4161-76. doi: 10.1088/0031-9155/56/13/027. Epub 2011 Jun 21. Phys Med Biol. 2011. PMID: 21693786 Free PMC article.
-
Bioelectromagnetic localization of a pacing catheter in the heart.Phys Med Biol. 1999 Oct;44(10):2565-78. doi: 10.1088/0031-9155/44/10/314. Phys Med Biol. 1999. PMID: 10533929
Cited by
-
Estimating uterine source current during contractions using magnetomyography measurements.PLoS One. 2018 Aug 23;13(8):e0202184. doi: 10.1371/journal.pone.0202184. eCollection 2018. PLoS One. 2018. PMID: 30138376 Free PMC article.