Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2009 Dec;34(10):1771-6.
doi: 10.1016/j.jhsa.2009.09.006.

Effect of partial versus complete circumferential repair on flexor tendon strength in cadavers

Affiliations
Comparative Study

Effect of partial versus complete circumferential repair on flexor tendon strength in cadavers

Umair Ansari et al. J Hand Surg Am. 2009 Dec.

Abstract

Purpose: This study investigated the strength of epitendinous repairs covering the palmar half of the tendon circumference only.

Methods: Two hundred porcine tendons were harvested from pig feet and separated into 2 equal groups. Group 1 tendons were sutured with a 2-strand core repair and group 2 tendons were sutured with a 4-strand core repair. Each group was then divided into 5 equal subgroups (n=20). Four of the subgroups were sutured with 1 of the following epitendinous repairs: 50% simple running (50SR), complete simple running (100SR), 50% Silfverskiold (50SK), or complete Silfverskiold (100SK). One sub-group (0C) had no epitendinous repair. The core suture material was 3-0 braided polyester (Tricon; Tyco Healthcare, Dominican Republic), and the circumferential suture material was 6-0 polypropylene (Prolene, Sumerville, NJ). The tendons were mechanically strained to failure, and force data were recorded.

Results: The 50SR and 50SK repairs significantly increased the force at 1-mm and 2-mm gap formation of both core repairs. The 50SR and 50SK repairs increased the ultimate force at failure of both core repairs by approximately 20%. Both 50% circumferential (50C) repairs increased repair strength at the points of initial gap formation more than at the point of ultimate force. The 50C repairs were approximately 50% as strong as the 100% circumferential (100C) repairs at 1-mm and 2-mm gap formation and approximately 70% as strong at the ultimate force of failure.

Conclusions: The 50C repairs increased the tensile strength of 2-strand and 4-strand tendon repairs in vitro. The prevention of early gapping was more significant than the increase of strength at failure.

PubMed Disclaimer

Publication types

LinkOut - more resources