PET measured evoked cerebral blood flow responses in an awake monkey
- PMID: 1997496
- DOI: 10.1038/jcbfm.1991.54
PET measured evoked cerebral blood flow responses in an awake monkey
Abstract
We have developed a method to measure task-related regional cerebral blood flow (BF) responses in an awake, trained monkey using positron emission tomography (PET) and H215O. We trained an animal with operant conditioning using only positive reinforcement to climb unassisted into a modified primate chair that was then positioned in the PET scanner. A special headholder and acrylic skull cap permitted precise placement and accurate repositioning. We measured BF qualitatively with bolus injection of H215O and 40-s scan. Each session included scans at rest interposed with scans during vibration of a forepaw. Regional responses were identified using subtraction image analysis. After global normalization, a resting image was subtracted on a pixel-by-pixel basis from a comparable image collected during vibration. The region of peak response occurred in contralateral sensorimotor cortex with a mean magnitude of 11.6% (+/- 3.2%) of the global mean value for 10 separate experiments, significantly greater than the mean qualitative BF change (0.4 +/- 3.6%; p less than 0.00001) in the same region for seven rest-rest pairs. This newly developed technique forms the basis for a wide variety of experiments.
Similar articles
-
Functional mapping of human sensorimotor cortex with 3D BOLD fMRI correlates highly with H2(15)O PET rCBF.J Cereb Blood Flow Metab. 1996 Sep;16(5):755-64. doi: 10.1097/00004647-199609000-00001. J Cereb Blood Flow Metab. 1996. PMID: 8784221
-
Vibration-induced regional cerebral blood flow responses in normal aging.J Cereb Blood Flow Metab. 1992 Jul;12(4):554-61. doi: 10.1038/jcbfm.1992.79. J Cereb Blood Flow Metab. 1992. PMID: 1618934
-
Accuracy of a method using short inhalation of (15)O-O(2) for measuring cerebral oxygen extraction fraction with PET in healthy humans.J Nucl Med. 2004 May;45(5):765-70. J Nucl Med. 2004. PMID: 15136624
-
Noninvasive functional brain mapping by change-distribution analysis of averaged PET images of H215O tissue activity.J Nucl Med. 1989 Feb;30(2):141-9. J Nucl Med. 1989. PMID: 2786929
-
[Cerebral blood flow measurement using H2(15)O intravenous injection and positron emission tomography: description of implementation and applications to cerebrovascular reactivity measurement].No To Shinkei. 1987 Jun;39(6):535-42. No To Shinkei. 1987. PMID: 3113465 Japanese.
Cited by
-
Using PET H2O15 brain imaging to study the functional-anatomical correlates of non-human primate communication.Methods. 2006 Mar;38(3):221-6. doi: 10.1016/j.ymeth.2005.08.003. Methods. 2006. PMID: 16466931 Free PMC article.
-
An Automated Motion Detection and Reward System for Animal Training.Cureus. 2015 Dec 4;7(12):e397. doi: 10.7759/cureus.397. Cureus. 2015. PMID: 26798573 Free PMC article.
-
PET measurement of dopamine D2 receptor-mediated changes in striatopallidal function.J Neurosci. 1997 May 1;17(9):3168-77. doi: 10.1523/JNEUROSCI.17-09-03168.1997. J Neurosci. 1997. PMID: 9096151 Free PMC article.
-
High-resolution optical imaging of functional brain architecture in the awake monkey.Proc Natl Acad Sci U S A. 1991 Dec 15;88(24):11559-63. doi: 10.1073/pnas.88.24.11559. Proc Natl Acad Sci U S A. 1991. PMID: 1763070 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Miscellaneous