Which device is more accurate to determine the stability/mobility of dental implants? A human cadaver study
- PMID: 20002537
- DOI: 10.1111/j.1365-2842.2009.02038.x
Which device is more accurate to determine the stability/mobility of dental implants? A human cadaver study
Abstract
Non-invasive devices including resonance frequency (RF) analysis and mobility measuring (MM) damping capacity assessment are used to measure implant stability/mobility. The aims of the study were to compare the primary stability of implant inserted into extraction sockets by using RF with cable, RF wireless and new wireless MM device, to clarify the relation between these devices and to understand the correlations between peri-implant bone levels and implant stability. A total of 30 screw-type implants (3.75 x 11 and 4.2 x 11 mm) were inserted into extraction sockets of eight mandibular pre-molar regions of human cadavers. The primary stability of implants was measured by three devices after insertion. Peri-implant vertical defects were created in millimetre increments ranging between 0 and 5 mm, and stability/mobility of implants were analysed. At placement, the mean implant stability quotient of RF with cable, RF wireless and MM device values was 46 +/- 1, 57.8 +/- 9 and -5.4 +/- 1, respectively. Statistical correlations were demonstrated between these devices (P = 0.001). Statistically significant differences were presented for all peri-implant detects ranging between 0 and 5 mm for RF with cable and RF wireless at all increments. However, only a significant decrease was found between 0 and 1 mm defects, and 4 and 5 mm defects in MM device. Although RF with cable and RF wireless seem to be suitable to detect peri-implant bone loss around implants in 1 mm increments, the new MM device may not be suitable to detect the 1 mm peri-implant bone changes in human dried cadaver mandibles.
Similar articles
-
Relationship between dental implant stability determined by resonance frequency analysis measurements and peri-implant vertical defects: an in vitro study.J Oral Rehabil. 2008 Oct;35(10):739-44. doi: 10.1111/j.1365-2842.2007.01840.x. Epub 2008 Apr 14. J Oral Rehabil. 2008. PMID: 18422511
-
Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.Clin Implant Dent Relat Res. 2009 Mar;11(1):52-8. doi: 10.1111/j.1708-8208.2008.00095.x. Epub 2008 Apr 1. Clin Implant Dent Relat Res. 2009. PMID: 18384400
-
Primary stability/mobility of 1-stage and 2-stage dental implants: a comparative in vitro study.Implant Dent. 2012 Dec;21(6):461-6. doi: 10.1097/ID.0b013e3182661615. Implant Dent. 2012. PMID: 23114827
-
Influence of implant geometry on primary insertion stability and simulated peri-implant bone loss: an in vitro study using resonance frequency analysis and damping capacity assessment.Int J Oral Maxillofac Implants. 2011 Mar-Apr;26(2):347-55. Int J Oral Maxillofac Implants. 2011. PMID: 21483888
-
A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants.Crit Rev Biomed Eng. 1998;26(4):275-91. doi: 10.1615/critrevbiomedeng.v26.i4.20. Crit Rev Biomed Eng. 1998. PMID: 10065892 Review.
Cited by
-
ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency.Int J Implant Dent. 2017 Oct 12;3(1):44. doi: 10.1186/s40729-017-0105-3. Int J Implant Dent. 2017. PMID: 29027158 Free PMC article.
-
Evaluation of Peri-Implant Bone Changes with Fractal Analysis.J Clin Med. 2025 May 29;14(11):3820. doi: 10.3390/jcm14113820. J Clin Med. 2025. PMID: 40507583 Free PMC article.
-
Updated secondary implant stability data of two dental implant systems. A retrospective cohort study.J Clin Exp Dent. 2017 Sep 1;9(9):e1121-e1128. doi: 10.4317/jced.54146. eCollection 2017 Sep. J Clin Exp Dent. 2017. PMID: 29075415 Free PMC article.
-
Fractal analysis as a useful predictor for determining osseointegration of dental implant? A retrospective study.Int J Implant Dent. 2021 Feb 25;7(1):14. doi: 10.1186/s40729-021-00296-0. Int J Implant Dent. 2021. PMID: 33629210 Free PMC article.
-
Clinical Validation of Dental Implant Stability by Newly Designed Damping Capacity Assessment Device during the Healing Period.Medicina (Kaunas). 2022 Oct 31;58(11):1570. doi: 10.3390/medicina58111570. Medicina (Kaunas). 2022. PMID: 36363526 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources