Toxicity of organic fluorophores used in molecular imaging: literature review
- PMID: 20003892
Toxicity of organic fluorophores used in molecular imaging: literature review
Abstract
Fluorophores are potentially useful for in vivo cancer diagnosis. Using relatively inexpensive and portable equipment, optical imaging with fluorophores permits real-time detection of cancer. However, fluorophores can be toxic and must be investigated before they can be administered safely to patients. A review of published literature on the toxicity of 19 widely used fluorophores was conducted by searching 26 comprehensive biomedical and chemical literature databases and analyzing the retrieved material. These fluorophores included Alexa Fluor 488 and 514, BODIPY FL, BODIPY R6G, Cy 5.5, Cy 7, cypate, fluorescein, indocyanine green, Oregon green, 8-phenyl BODIPY, rhodamine 110, rhodamine 6G, rhodamine X, rhodol, TAMRA, Texas red, and Tokyo green. Information regarding cytotoxicity, tissue toxicity, in vivo toxicity, and mutagenicity was included. Considerable toxicity-related information was available for the Food and Drug Administration (FDA)-approved compounds indocyanine green and fluorescein, but published information on many of the non-FDA-approved fluorophores was limited. The information located was encouraging because the amounts of fluorophore used in molecular imaging probes are typically much lower than the toxic doses described in the literature. Ultimately, the most effective and appropriate probes for use in patients will be determined by their fluorescent characteristics and the safety of the conjugates.
Similar articles
-
A comparison of the emission efficiency of four common green fluorescence dyes after internalization into cancer cells.Bioconjug Chem. 2006 Nov-Dec;17(6):1426-31. doi: 10.1021/bc0601626. Bioconjug Chem. 2006. PMID: 17105220 Free PMC article.
-
Staining and peeling of the internal limiting membrane using a fluorescent dye (Rhodamine 6 G).Br J Ophthalmol. 2008 Sep;92(9):1265-8. doi: 10.1136/bjo.2008.141911. Epub 2008 Jun 27. Br J Ophthalmol. 2008. PMID: 18586900
-
In vivo toxicity study of rhodamine 6G in the rat retina.Invest Ophthalmol Vis Sci. 2008 May;49(5):2120-6. doi: 10.1167/iovs.07-1476. Invest Ophthalmol Vis Sci. 2008. PMID: 18436844
-
Indocyanine green fluorescence imaging in the surgical management of liver cancers: current facts and future implications.J Visc Surg. 2014 Apr;151(2):117-24. doi: 10.1016/j.jviscsurg.2013.11.003. Epub 2014 Jan 21. J Visc Surg. 2014. PMID: 24461273 Review.
-
Biomedical applications of fluorescence imaging in vivo.Comp Med. 2004 Dec;54(6):635-44. Comp Med. 2004. PMID: 15679261 Review.
Cited by
-
CEACAM6 is upregulated by Helicobacter pylori CagA and is a biomarker for early gastric cancer.Oncotarget. 2016 Aug 23;7(34):55290-55301. doi: 10.18632/oncotarget.10528. Oncotarget. 2016. PMID: 27421133 Free PMC article.
-
Evolving from Laboratory Toys towards Life-Savers: Small-Scale Magnetic Robotic Systems with Medical Imaging Modalities.Micromachines (Basel). 2021 Oct 26;12(11):1310. doi: 10.3390/mi12111310. Micromachines (Basel). 2021. PMID: 34832722 Free PMC article. Review.
-
A 2,7-dichlorofluorescein derivative to monitor microcalcifications.Mol Syst Des Eng. 2022 Nov 1;7(11):1415-1421. doi: 10.1039/d2me00185c. Epub 2022 Oct 10. Mol Syst Des Eng. 2022. PMID: 37927331 Free PMC article.
-
Extracting quantitative biological information from bright-field cell images using deep learning.Biophys Rev (Melville). 2021 Jul 20;2(3):031401. doi: 10.1063/5.0044782. eCollection 2021 Sep. Biophys Rev (Melville). 2021. PMID: 38505631 Free PMC article.
-
Investigation of artificial intelligence integrated fluorescence endoscopy image analysis with indocyanine green for interpretation of precancerous lesions in colon cancer.PLoS One. 2023 May 25;18(5):e0286189. doi: 10.1371/journal.pone.0286189. eCollection 2023. PLoS One. 2023. PMID: 37228164 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Other Literature Sources