Is kyphoplasty better than vertebroplasty in restoring normal mechanical function to an injured spine?
- PMID: 20004264
- DOI: 10.1016/j.bone.2009.11.036
Is kyphoplasty better than vertebroplasty in restoring normal mechanical function to an injured spine?
Abstract
Introduction: Kyphoplasty is gaining in popularity as a treatment for painful osteoporotic vertebral body fracture. It has the potential to restore vertebral shape and reduce spinal deformity, but the actual clinical and mechanical benefits of kyphoplasty remain unclear. In a cadaveric study, we compare the ability of vertebroplasty and kyphoplasty to restore spine mechanical function, and vertebral body shape, following vertebral fracture.
Methods: Fifteen pairs of thoracolumbar "motion segments" (two vertebrae with the intervening disc and ligaments) were obtained from cadavers aged 42-96 years. All specimens were compressed to induce vertebral body fracture. Then one of each pair underwent vertebroplasty and the other kyphoplasty, using 7 ml of polymethylmethacrylate cement. Augmented specimens were compressed for 2 hours to allow consolidation. At each stage of the experiment, motion segment stiffness was measured in bending and compression, and the distribution of loading on the vertebrae was determined by pulling a miniature pressure transducer through the intervertebral disc. Disc pressure measurements were performed in flexed and extended postures with a compressive load of 1.0-1.5 kN. They revealed the intradiscal pressure (IDP) which acts on the central vertebral body, and they enabled compressive load-bearing by the neural arch (F(N)) to be calculated. Changes in vertebral height and wedge angle were assessed from radiographs. The volume of leaked cement was determined by water displacement. Volumetric bone mineral density (BMD) of each vertebral body was calculated using DXA and water displacement.
Results: Vertebral fracture reduced motion segment compressive stiffness by 55%, and bending stiffness by 39%. IDP fell by 61-88%, depending on posture. F(N) increased from 15% to 36% in flexion and from 30% to 58% in extension (P<0.001). Fracture reduced vertebral height by an average 0.94 mm and increased vertebral wedging by 0.95 degrees (P<0.001). Vertebroplasty and kyphoplasty were equally effective in partially restoring all aspects of mechanical function (including stiffness, IDP, and F(N)), but vertebral wedging was reduced only by kyphoplasty (P<0.05). Changes in mechanical function and vertebral wedging were largely maintained after consolidation, but height restoration was not. Cement leakage was similar for both treatments.
Conclusions: Vertebroplasty and kyphoplasty were equally effective at restoring mechanical function to an injured spine. Only kyphoplasty was able to reverse minor vertebral wedging.
Copyright 2009 Elsevier Inc. All rights reserved.
Similar articles
-
Mechanical efficacy of vertebroplasty: influence of cement type, BMD, fracture severity, and disc degeneration.Bone. 2007 Apr;40(4):1110-9. doi: 10.1016/j.bone.2006.11.021. Epub 2007 Jan 16. Bone. 2007. PMID: 17229596
-
Vertebroplasty: only small cement volumes are required to normalize stress distributions on the vertebral bodies.Spine (Phila Pa 1976). 2009 Dec 15;34(26):2865-73. doi: 10.1097/BRS.0b013e3181b4ea1e. Spine (Phila Pa 1976). 2009. PMID: 20010394
-
Is kyphoplasty better than vertebroplasty at restoring form and function after severe vertebral wedge fractures?Spine J. 2015 Apr 1;15(4):721-32. doi: 10.1016/j.spinee.2014.11.017. Epub 2014 Nov 28. Spine J. 2015. PMID: 25450656
-
Vertebroplasty and kyphoplasty: reasons for concern?Orthop Clin North Am. 2009 Oct;40(4):465-71, viii. doi: 10.1016/j.ocl.2009.05.004. Orthop Clin North Am. 2009. PMID: 19773051 Review.
-
Biomechanics of vertebral compression fractures and clinical application.Arch Orthop Trauma Surg. 2011 Dec;131(12):1703-10. doi: 10.1007/s00402-011-1355-9. Epub 2011 Jul 31. Arch Orthop Trauma Surg. 2011. PMID: 21805360 Review.
Cited by
-
Secondary balloon kyphoplasty for new vertebral compression fracture after initial single-level balloon kyphoplasty for osteoporotic vertebral compression fracture.Eur Spine J. 2017 Jul;26(7):1842-1851. doi: 10.1007/s00586-016-4784-x. Epub 2016 Oct 21. Eur Spine J. 2017. PMID: 27770334
-
Vertebral deformity arising from an accelerated "creep" mechanism.Eur Spine J. 2012 Sep;21(9):1684-91. doi: 10.1007/s00586-012-2279-y. Epub 2012 Mar 25. Eur Spine J. 2012. PMID: 22447410 Free PMC article.
-
Vertebroplasty and Kyphoplasty Can Restore Normal Spine Mechanics following Osteoporotic Vertebral Fracture.J Osteoporos. 2010 Jun 20;2010:729257. doi: 10.4061/2010/729257. J Osteoporos. 2010. PMID: 20981329 Free PMC article.
-
Biomechanical preservation of lumbar spine stability and motion with an intraosseous implant following vertebral body osteotomy.Eur Spine J. 2025 Jun;34(6):2467-2477. doi: 10.1007/s00586-025-08871-4. Epub 2025 Apr 19. Eur Spine J. 2025. PMID: 40252084
-
Kyphoplasty in osteoporotic vertebral compression fractures--guidelines and technical considerations.J Orthop Surg Res. 2011 Aug 19;6:43. doi: 10.1186/1749-799X-6-43. J Orthop Surg Res. 2011. PMID: 21854577 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous