Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2010 Jan;28(1):1-7.
doi: 10.1016/j.ajem.2008.09.001.

Ultrasonography-guided peripheral intravenous catheter survival in ED patients with difficult access

Affiliations
Clinical Trial

Ultrasonography-guided peripheral intravenous catheter survival in ED patients with difficult access

James M Dargin et al. Am J Emerg Med. 2010 Jan.

Abstract

Objectives: We determined the survival and complications of ultrasonography-guided peripheral intravenous (IV) catheters in emergency department (ED) patients with difficult peripheral access.

Methods: This was a prospective, observational study conducted in an academic hospital from April to July of 2007. We included consecutive adult ED patients with difficult access who had ultrasonography-guided peripheral IVs placed. Operators completed data sheets and researchers examined admitted patients daily to assess outcomes. The primary outcome was IV survival >96 hours. As a secondary outcome, we recorded IV complications, including central line placement. We used descriptive statistics, univariate survival analysis with Kaplan Meier, and log-rank tests for data analysis.

Results: Seventy-five patients were enrolled. The average age was 52 years. Fifty-three percent were male, 21% obese, and 13% had a history of injection drug use. The overall IV survival rate was 56% (95% confidence interval, 44%-67%) with a median survival of 26 hours (interquartile range [IQR], 8-61). Forty-seven percent of IVs failed within 24 hours, most commonly due to infiltration. Although 47 (63%) operators reported that a central line would have been required if peripheral access was unobtainable, only 5 (7%; 95% confidence interval, 2%-15%) patients underwent central venous catheterization. Only 1 central line was placed as a result of ultrasonography-guided IV failure. We observed no infectious or thrombotic complications.

Conclusion: Despite a high premature failure rate, ultrasonography-guided peripheral IVs appear to be an effective alternative to central line placement in ED patients with difficult access.

PubMed Disclaimer

Similar articles

Cited by

Publication types