Evaluation of three multiplex flow immunoassays compared to an enzyme immunoassay for the detection and differentiation of IgG class antibodies to herpes simplex virus types 1 and 2
- PMID: 20007366
- PMCID: PMC2815519
- DOI: 10.1128/CVI.00325-09
Evaluation of three multiplex flow immunoassays compared to an enzyme immunoassay for the detection and differentiation of IgG class antibodies to herpes simplex virus types 1 and 2
Abstract
The diagnosis of herpes simplex virus (HSV) infections is routinely made based on clinical findings and supported by laboratory testing using PCR or viral culture. However, in instances of subclinical or unrecognized HSV infection, serologic testing for IgG class antibodies to type-specific HSV glycoprotein G (gG) may be useful. This study evaluated and compared the performances of three multiplex flow immunoassays (AtheNA Multi-Lyte [Zeus Scientific], BioPlex 2200 [Bio-Rad Laboratories], and Plexus HerpeSelect [Focus Diagnostics]) for the simultaneous detection of gG type-specific IgG antibodies to HSV types 1 and 2 (HSV-1 and HSV-2). Serum specimens (n = 505) submitted for routine gG type-specific HSV IgG testing by enzyme immunoassay (EIA) (HerpeSelect; Focus Diagnostics) were also tested by the three multiplex flow immunoassays. Specimens showing discordant results were tested by HSV type-specific Western blotting (WB). For HSV-1 IgG, the AtheNA, BioPlex, and Plexus assays demonstrated agreements of 94.9% (479/505 specimens), 97.8% (494/505 specimens), and 97.4% (492/505 specimens), respectively, with the results of EIA. For HSV-2 IgG, the AtheNA, BioPlex, and Plexus assays showed agreements of 87.9% (444/505 specimens), 97.2% (491/505 specimens), and 96.8% (489/505 specimens), respectively, with EIA results. Timing studies showed that the AtheNA, BioPlex, and Plexus assays could provide complete analysis of 90 serum specimens in 3.1, 1.5, and 2.9 h, respectively, versus 3.1 h by EIA. These findings suggest that the gG type-specific HSV IgG multiplex immunoassays may be beneficial to high-volume clinical laboratories experiencing significant increases in the number of specimens submitted for HSV serologic testing. The evaluated systems provide comparable results to those of EIA, while reducing hands-on time and eliminating the necessity to aliquot specimens prior to testing.
Similar articles
-
Multiplex detection of IgM and IgG class antibodies to Toxoplasma gondii, rubella virus, and cytomegalovirus using a novel multiplex flow immunoassay.Clin Vaccine Immunol. 2010 Nov;17(11):1734-8. doi: 10.1128/CVI.00332-10. Epub 2010 Sep 22. Clin Vaccine Immunol. 2010. PMID: 20861325 Free PMC article.
-
Evaluation of an enzyme immunoassay system for measuring herpes simplex virus (HSV) type 1-specific and HSV type 2-specific IgG antibodies.J Clin Lab Anal. 2000;14(1):13-6. doi: 10.1002/(sici)1098-2825(2000)14:1<13::aid-jcla3>3.0.co;2-c. J Clin Lab Anal. 2000. PMID: 10645979 Free PMC article.
-
Performance of a novel test for IgM and IgG antibodies in subjects with culture-documented genital herpes simplex virus-1 or -2 infection.Clin Microbiol Infect. 2006 May;12(5):463-9. doi: 10.1111/j.1469-0691.2006.01370.x. Clin Microbiol Infect. 2006. PMID: 16643524
-
Performance and use of HSV type-specific serology test kits.Herpes. 2002 Jul;9(2):38-45. Herpes. 2002. PMID: 12106510 Review.
-
Herpes serology for dermatologists.Arch Dermatol. 2000 Sep;136(9):1158-61. doi: 10.1001/archderm.136.9.1158. Arch Dermatol. 2000. PMID: 10987876 Review.
Cited by
-
Multiplex detection of IgM and IgG class antibodies to Toxoplasma gondii, rubella virus, and cytomegalovirus using a novel multiplex flow immunoassay.Clin Vaccine Immunol. 2010 Nov;17(11):1734-8. doi: 10.1128/CVI.00332-10. Epub 2010 Sep 22. Clin Vaccine Immunol. 2010. PMID: 20861325 Free PMC article.
-
Development and validation of protein microarray technology for simultaneous inflammatory mediator detection in human sera.Mediators Inflamm. 2014;2014:820304. doi: 10.1155/2014/820304. Epub 2014 Oct 14. Mediators Inflamm. 2014. PMID: 25382942 Free PMC article.
-
Performance of the BioPlex 2200 multiplexing immunoassay platform for the detection of herpes simplex virus type 2 specific antibodies in African settings.Clin Vaccine Immunol. 2011 Jul;18(7):1191-3. doi: 10.1128/CVI.05003-11. Epub 2011 May 11. Clin Vaccine Immunol. 2011. PMID: 21562116 Free PMC article.
-
Performance characteristics of highly automated HSV-1 and HSV-2 IgG testing.J Clin Microbiol. 2024 Jun 12;62(6):e0026324. doi: 10.1128/jcm.00263-24. Epub 2024 Apr 30. J Clin Microbiol. 2024. PMID: 38687020 Free PMC article.
-
Light microscopy, culture, molecular, and serologic methods for detection of herpes simplex virus.J Clin Microbiol. 2014 Jan;52(1):2-8. doi: 10.1128/JCM.01966-13. Epub 2013 Oct 16. J Clin Microbiol. 2014. PMID: 24131689 Free PMC article. Review.
References
-
- Arvin, A. M. 2002. Debate: the argument against. Should all pregnant women be offered type-specific serological screening for HSV infection? Herpes 9:48-50. - PubMed
-
- Ashley, R., A. Cent, V. Maggs, A. Nahmias, and L. Corey. 1991. Inability of enzyme immunoassays to discriminate between infections with herpes simplex virus types 1 and 2. Ann. Intern. Med. 115:520-526. - PubMed
-
- Ashley, R. L. 2002. Performance and use of HSV type-specific serology test kits. Herpes 9:38-45. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical