Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1991 Mar 15;67(7):622-7.
doi: 10.1016/0002-9149(91)90902-w.

Effect of heart rate on left ventricular diastolic transmitral flow velocity patterns assessed by Doppler echocardiography in normal subjects

Affiliations

Effect of heart rate on left ventricular diastolic transmitral flow velocity patterns assessed by Doppler echocardiography in normal subjects

M R Harrison et al. Am J Cardiol. .

Abstract

Although a number of factors, including age and ventricular loading, are known to influence the pattern of left ventricular (LV) filling as depicted by Doppler echocardiographic transmitral flow velocities, few and conflicting data are available regarding the influence of heart rate (HR). Therefore, 20 volunteers (mean age 30 years) were evaluated with pulsed-wave Doppler echocardiography, performed with the sample volume placed at the mitral anulus level in the apical 4-chamber projection. Transmitral flow measurements comprised peak and integrated early passive (E) and late atrial (A) filling velocities and the slope of velocity decline from peak E filling. Measurements were recorded during baseline (sinus rhythm, mean 70 beats/min) and during transesophageal atrial pacing (mean 88 beats/min). LV end-diastolic dimension, mean arterial pressure and PR interval (corrected for pacing-induced delay in interatrial conduction time) were unchanged during pacing versus baseline measurements. Peak and integrated E filling velocities averaged 0.59 +/- 0.09 m/s and 6 +/- 1 cm, respectively, at baseline and were not significantly greater at the higher HR. In contrast, baseline peak and integrated A velocities averaged 0.37 +/- 0.06 m/s and 2.3 +/- 0.7 cm, respectively, but were significantly greater at the higher HR (0.5 +/- 0.07 m/s and 3.2 +/- 1.1 cm, respectively [p less than 0.003 vs baseline for each]). Further analysis of a subgroup of 9 subjects for whom Doppler measurements were available at 3 HRs (sinus 70; pacing 80 and 90) yielded strong evidence for a linear relation between HR and peak A velocity (A = 0.008 HR - 0.21, with p less than 0.0001 for significance of the linear trend).(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

LinkOut - more resources