FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: II. Dosimetric calculations
- PMID: 20009181
- DOI: 10.1088/0031-9155/55/1/010
FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: II. Dosimetric calculations
Abstract
Female and male adult human phantoms, called FASH (Female Adult meSH) and MASH (Male Adult meSH), have been developed in the first part of this study using 3D animation software and anatomical atlases to replace the image-based FAX06 and the MAX06 voxel phantoms. 3D modelling methods allow for phantom development independent from medical images of patients, volunteers or cadavers. The second part of this study investigates the dosimetric implications for organ and tissue equivalent doses due to the anatomical differences between the new and the old phantoms. These differences are mainly caused by the supine position of human bodies during scanning in order to acquire digital images for voxel phantom development. Compared to an upright standing person, in image-based voxel phantoms organs are often coronally shifted towards the head and sometimes the sagittal diameter of the trunk is reduced by a gravitational change of the fat distribution. In addition, volumes of adipose and muscle tissue shielding internal organs are sometimes too small, because adaptation of organ volumes to ICRP-based organ masses often occurs at the expense of general soft tissues, such as adipose, muscle or unspecified soft tissue. These effects have dosimetric consequences, especially for partial body exposure, such as in x-ray diagnosis, but also for whole body external exposure and for internal exposure. Using the EGSnrc Monte Carlo code, internal and external exposure to photons and electrons has been simulated with both pairs of phantoms. The results show differences between organ and tissue equivalent doses for the upright standing FASH/MASH and the image-based supine FAX06/MAX06 phantoms of up to 80% for external exposure and up to 100% for internal exposure. Similar differences were found for external exposure between FASH/MASH and REGINA/REX, the reference voxel phantoms of the International Commission on Radiological Protection. Comparison of effective doses for external photon exposure showed good agreement between FASH/MASH and REGINA/REX, but large differences between FASH/MASH and the mesh-based RPI_AM and the RPI_AF phantoms, developed at the Rensselaer Polytechnic Institute (RPI).
Similar articles
-
FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: I. Development of the anatomy.Phys Med Biol. 2010 Jan 7;55(1):133-62. doi: 10.1088/0031-9155/55/1/009. Phys Med Biol. 2010. PMID: 20009183
-
Posture-specific phantoms representing female and male adults in Monte Carlo-based simulations for radiological protection.Phys Med Biol. 2010 Aug 7;55(15):4399-430. doi: 10.1088/0031-9155/55/15/014. Epub 2010 Jul 20. Phys Med Biol. 2010. PMID: 20647610
-
Deformable adult human phantoms for radiation protection dosimetry: anthropometric data representing size distributions of adult worker populations and software algorithms.Phys Med Biol. 2010 Jul 7;55(13):3789-811. doi: 10.1088/0031-9155/55/13/015. Epub 2010 Jun 15. Phys Med Biol. 2010. PMID: 20551505 Free PMC article.
-
A Robust Algorithm for Voxel-to-Polygon Mesh Phantom Conversion.2019 Aug 28. In: Makarov S, Horner M, Noetscher G, editors. Brain and Human Body Modeling: Computational Human Modeling at EMBC 2018 [Internet]. Cham (CH): Springer; 2019. Chapter 17. 2019 Aug 28. In: Makarov S, Horner M, Noetscher G, editors. Brain and Human Body Modeling: Computational Human Modeling at EMBC 2018 [Internet]. Cham (CH): Springer; 2019. Chapter 17. PMID: 31725248 Free Books & Documents. Review.
-
Voxel-based computational models of real human anatomy: a review.Radiat Environ Biophys. 2004 Feb;42(4):229-35. doi: 10.1007/s00411-003-0221-8. Epub 2004 Jan 17. Radiat Environ Biophys. 2004. PMID: 14730450 Review.
Cited by
-
Thymus ad astra, or spaceflight-induced thymic involution.Front Immunol. 2025 Jan 24;15:1534444. doi: 10.3389/fimmu.2024.1534444. eCollection 2024. Front Immunol. 2025. PMID: 39926601 Free PMC article. Review.
-
Deformable torso phantoms of Chinese adults for personalized anatomy modelling.J Anat. 2018 Jul;233(1):121-134. doi: 10.1111/joa.12815. Epub 2018 Apr 16. J Anat. 2018. PMID: 29663370 Free PMC article.
-
Activity quantification and dosimetry in radiopharmaceutical therapy with reference to 177Lutetium.Front Nucl Med. 2024 Mar 28;4:1355912. doi: 10.3389/fnume.2024.1355912. eCollection 2024. Front Nucl Med. 2024. PMID: 39355215 Free PMC article. Review.
-
Comment on "Hybrid computational phantoms for medical dose reconstruction" by Bolch et al.Radiat Environ Biophys. 2010 Aug;49(3):499-500; author reply 501-2. doi: 10.1007/s00411-010-0277-1. Epub 2010 Mar 23. Radiat Environ Biophys. 2010. PMID: 20309705 No abstract available.
-
Presenting and simulating an innovative model of liver phantom and applying two methods for dosimetry of it in neutron radiation therapy.Rep Pract Oncol Radiother. 2017 Jan-Feb;22(1):42-51. doi: 10.1016/j.rpor.2016.09.013. Epub 2016 Oct 27. Rep Pract Oncol Radiother. 2017. PMID: 27829819 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources