Determination of fluoride using ion-selective electrodes in the presence of aluminum
- PMID: 20009331
- DOI: 10.2116/analsci.25.1437
Determination of fluoride using ion-selective electrodes in the presence of aluminum
Abstract
We describe a method for determining fluoride with ion-selective electrodes (ISEs). Tartrate and Tris-based total ionic strength adjustment buffers (TISABs) were found to lower the interference from aluminum to a greater extent than conventional citrate-based TISABs. We adopted a solid TISAB addition method that is simple to perform, and can be carried out without lowering the level of fluoride. The apparent recovery of fluoride was 95% or higher, even at 500 mg L(-1) of Al3+ when a tartrate and Tris-based TISAB was used. Interferences from common ions were not observed at 100 mg L(-1) levels. We determined the fluoride content in solid silicate samples with ISEs without preliminary steam distillation after alkali fusion processing. Adding a solid TISAB mixture consisting of tartaric acid, sodium tartrate, and Tris, however, eliminated any interference from high levels of aluminum and sodium and potassium carbonates. The proposed analytical method was also applied to the determination of fluoride in geochemical reference samples.
Similar articles
-
Determination of total fluoride in boron-containing solutions.Anal Sci. 2010;26(5):603-6. doi: 10.2116/analsci.26.603. Anal Sci. 2010. PMID: 20467138
-
Comparison of total ionic strength adjustment buffers III and IV in the measurement of fluoride concentration of teas.Nutr Health. 2018 Jun;24(2):111-119. doi: 10.1177/0260106018758781. Epub 2018 Apr 4. Nutr Health. 2018. PMID: 29618287 Free PMC article.
-
[Comparison and optimization of total ionic strength adjustment buffer during detecting fluoride in trace serum sample by fluoride ion selective electrode method].Wei Sheng Yan Jiu. 2016 Mar;45(2):194-9. Wei Sheng Yan Jiu. 2016. PMID: 27301213 Chinese.
-
Simultaneous flow injection determination of calcium and fluoride in natural and borehole water with conventional ion-selective electrodes in series.Talanta. 1999 Aug 9;49(5):1017-22. doi: 10.1016/s0039-9140(99)00060-0. Talanta. 1999. PMID: 18967678
-
Solid contact potassium selective electrodes for biomedical applications - a review.Talanta. 2016 Nov 1;160:56-65. doi: 10.1016/j.talanta.2016.06.050. Epub 2016 Jun 25. Talanta. 2016. PMID: 27591587 Review.
Cited by
-
Spectroscopic Determination of Fluoride Using Eriochrome Black T (EBT) as a Spectrophotometric Reagent from Groundwater.Int J Anal Chem. 2021 Dec 28;2021:2045491. doi: 10.1155/2021/2045491. eCollection 2021. Int J Anal Chem. 2021. PMID: 34992659 Free PMC article.
LinkOut - more resources
Full Text Sources