Background: Gastric leak and hemorrhage are the most important challenges after laparoscopic sleeve gastrectomy (LSG). In order to reduce these complications, the staple line can be reinforced by absorbable sutures or by the use of glycolide trimethylene carbonate copolymer onto the linear stapler (Gore Seamguard; W.L. Gore & Associates, Inc, Flagstaff, AZ). To our knowledge, there are no randomized studies showing the utility of staple line reinforcement during LSG. The purpose of this study was to randomly compare three techniques in LSG: no staple line reinforcement (group 1), buttressing of the staple line with Gore Seamguard (group 2), and staple line suturing (group 3).
Methods: Between January 2008 and February 2009, 75 patients were prospectively and randomly enrolled in the three different techniques of handling the staple line during LSG. The patient groups were similar (NS).
Results: Mean operative time to perform the stomach sectioning was 15.9 +/- 5.9 min (group 1), 20.8 +/- 8.1 min (group 2), and 30.8 +/- 10.1 min (group 3) (p < 0.001). Mean total operative time was 47.4 +/- 10.7 min (group 1), 48.9 +/- 18.4 min (group 2), and 59.9 +/- 19.6 min (group 3) (p = 0.02). Mean blood loss during stomach sectioning was 19.5 +/- 21.3 mL (group 1), 3.6 +/- 4.7 mL (group 2), and 16.7 +/- 23.5 mL (group 3) (p < 0.001). Mean total blood loss was 48.9 +/- 67.1 mL (group 1), 32.5 +/- 46.5 mL (group 2), and 61.9 +/- 69.4 mL (group 3) (p = 0.03). Mean number of stapler cartridges used was 5.6 +/- 0.7 (group 1), 5.7 +/- 0.7 (group 2), and 5.8 +/- 0.6 (group 3) (NS). Postoperative leak affected one patient (group 1), two patients (group 2), and one patient (group 3) (NS). Mean hospital stay was 3.6 +/- 1.4 days (group 1), 3.9 +/- 1.5 days (group 2), and 2.8 +/- 0.8 days (group 3) (p = 0.01).
Conclusions: In LSG, buttressing the staple line with Gore Seamguard statistically reduces blood loss during stomach sectioning as well as overall blood loss. No staple line reinforcement statistically decreases the time to perform stomach sectioning and the total operative time. No significant difference is evidenced in terms of postoperative leak between the three techniques of LSG.
Similar articles
-
Reinforcing the staple line during laparoscopic sleeve gastrectomy: prospective randomized clinical study comparing two different techniques. Preliminary results.Obes Surg. 2012 Jan;22(1):42-6. doi: 10.1007/s11695-011-0421-2. Obes Surg. 2012. PMID: 21533880 Clinical Trial.
-
Staple Line Reinforcement Using SEAMGUARD® versus Suture Over Sewing During Laparoscopic Sleeve Gastrectomy for Super Morbidly Obese Patients: A Prospective Randomized Clinical Trial.Surg Technol Int. 2023 Dec 15;43:57-60. doi: 10.52198/23.STI.43.GS1704. Surg Technol Int. 2023. PMID: 37972556 Clinical Trial.
-
Comparison Between Stable Line Reinforcement by Barbed Suture and Non-reinforcement in Sleeve Gastrectomy: a Randomized Prospective Controlled Study.Obes Surg. 2018 Aug;28(8):2157-2164. doi: 10.1007/s11695-018-3175-2. Obes Surg. 2018. PMID: 29508273 Clinical Trial.
-
Preventing staple-line leak in sleeve gastrectomy: reinforcement with bovine pericardium vs. oversewing.Obes Surg. 2013 Nov;23(11):1915-21. doi: 10.1007/s11695-013-1062-4. Obes Surg. 2013. PMID: 23975327 Review.
-
Is There Necessity for Oversewing the Staple Line During Laparoscopic Sleeve Gastrectomy? An Updated Systematic Review and Meta-Analysis of Randomized Controlled Trials.J Invest Surg. 2020 Oct;33(9):839-850. doi: 10.1080/08941939.2019.1665380. Epub 2019 Dec 5. J Invest Surg. 2020. PMID: 31805796
Cited by
-
Laparoscopic sleeve gastrectomy with staple line buttress reinforcement in 116 consecutive morbidly obese patients.Obes Surg. 2012 Apr;22(4):560-4. doi: 10.1007/s11695-012-0598-z. Obes Surg. 2012. PMID: 22258197
-
Standardised Sleeve Gastrectomy Without Reinforcement.JSLS. 2018 Jul-Sep;22(3):e2018.00015. doi: 10.4293/JSLS.2018.00015. JSLS. 2018. PMID: 30275674 Free PMC article.
-
A comparative study between staple line reinforcement during laparoscopic sleeve gastrectomy and no reinforcement: an Egyptian experience.Surg Endosc. 2023 Dec;37(12):9318-9325. doi: 10.1007/s00464-023-10497-w. Epub 2023 Oct 27. Surg Endosc. 2023. PMID: 37891370 Free PMC article.
-
Indocyanine Green Fluorescent Angiography During Laparoscopic Sleeve Gastrectomy: Preliminary Results.Obes Surg. 2019 Dec;29(12):3786-3790. doi: 10.1007/s11695-019-04085-y. Obes Surg. 2019. PMID: 31290111 Clinical Trial.
-
Management of Staple Line Leaks Following Sleeve Gastrectomy-a Systematic Review.Obes Surg. 2019 Sep;29(9):2759-2772. doi: 10.1007/s11695-019-03896-3. Obes Surg. 2019. PMID: 31062278
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous