Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Jun;19(6):995-1003.
doi: 10.1007/s00586-009-1241-0. Epub 2009 Dec 15.

Preliminary study: reliability of the spinal wheel. A novel device to measure spinal postures applied to sitting and standing

Affiliations

Preliminary study: reliability of the spinal wheel. A novel device to measure spinal postures applied to sitting and standing

Liba Sheeran et al. Eur Spine J. 2010 Jun.

Abstract

Postural re-education is an integral part of physiotherapy management in patients with back pain. Although the link between posture and back pain is largely unknown, postural re-education is performed on the premise of optimizing spinal alignment to minimize stresses on the passive structures of the spine, to facilitate optimal muscular support and thus to prevent possible damage and further pain. A reliable and clinically meaningful measurement of spinal postures to monitor such interventions remains challenging. This study evaluated within-day (intra-tester, inter-tester) and between-day (test-retest) reliability of a novel spinal wheel device measuring thoracic and lumbar postures during sitting and standing. 17 healthy volunteers (age 39.5 +/- 5.4, BMI 25 +/- 9.2; 9 males) were measured three times, by three testers, on two separate occasions (1 week apart). The angular change between C7 and T12 and between T12 and S1 provided thoracic and lumbar curvatures, respectively. Intra-class correlation coefficient (ICC) with 95% confidence intervals and typical error were calculated. Excellent reliability was demonstrated with intra-tester ICCs between 0.947 and 0.980 and typical error between 1.7 degrees and 3.7 degrees and inter-tester ICCs between 0.949 and 0.986 and typical error between 2.0 degrees and 4.7 degrees. Test-retest reliability was high with ICCs 0.719-0.908 and typical error between 4.0 degrees and 7.4 degrees. In conclusion, the spinal wheel demonstrated excellent within-day and high between-day reliability. The device may be used in conjunction with 2D camcorder to provide clinically useful visual evaluation of postures for assessment, intervention monitoring, and feedback during postural re-education.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Spinal wheel
Fig. 2
Fig. 2
Method of using spinal wheel
Fig. 3
Fig. 3
Graphical representation of spinal curvature measurement (three trials) in a single subject

References

    1. O’Sullivan PB, Mitchell T, Bulich P, Waller R, Holte J. The relationship between posture and back muscle endurance in industrial workers with flexion-related low back pain. Man Ther. 2006;11:264–271. doi: 10.1016/j.math.2005.04.004. - DOI - PubMed
    1. Dankaerts W, O’Sullivan P, Burnett A, Straker L. Differences in sitting postures are associated with nonspecific chronic low back pain disorders when patients are subclassified. Spine. 2006;31:698–704. doi: 10.1097/01.brs.0000202532.76925.d2. - DOI - PubMed
    1. Dankaerts W, O’Sullivan P, Burnett A, Straker L. Altered patterns of superficial trunk muscle activation during sitting in nonspecific chronic low back pain patients: importance of subclassification. Spine. 2006;31:2017–2023. doi: 10.1097/01.brs.0000228728.11076.82. - DOI - PubMed
    1. Panjabi MM. Clinical spinal instability and low back pain. J Electromyogr Kinesiol. 2003;13:371–379. doi: 10.1016/S1050-6411(03)00044-0. - DOI - PubMed
    1. O’Sullivan PB, Grahamslaw KM, Kendell M, Lapenskie SC, Moller NE, Richards KV. The effect of different standing and sitting postures on trunk muscle activity in a pain-free population. Spine. 2002;27:1238–1244. doi: 10.1097/00007632-200206010-00019. - DOI - PubMed

Publication types

LinkOut - more resources