Sensitive determination of epinephrine in pharmaceutical preparation by flow injection coupled with chemiluminescence detection and mechanism study
- PMID: 20017128
- DOI: 10.1002/bio.1186
Sensitive determination of epinephrine in pharmaceutical preparation by flow injection coupled with chemiluminescence detection and mechanism study
Abstract
A novel, rapid and sensitive method was described for the determination of epinephrine (EP) using flow injection analysis coupled with chemiluminescence (CL) detection, which based on EP enhanced the weak CL emission of luminol-KIO(4) system in NaOH solution. Parameters affecting the CL intensity and reproducibility were optimized systematically. Under the optimized experiment conditions, the net CL intensity was proportional to the concentration of EP in the range of 5.0 × 10(-8) to 1.5 × 10(-6) mol/L with a detection limit of 1.9 × 10(-9) mol/L. The relative standard deviation (RSD) was found to be 0.7% for 13 replicate determinations of 3.0 × 10(-7) mol/L EP. The applicability of the proposed method was illustrated in the determination of EP in pharmaceutical preparation. The recoveries of EP at different levels in EP hydrochloride injection were between 95.4 and 104.7%. One assay procedure takes only 27 s, and the sampling rate was calculated about to be 130 samples/h. The possible mechanism of the enhanced CL intensity was studied by examining CL spectra and UV-vis spectra.
Copyright © 2009 John Wiley & Sons, Ltd.
Similar articles
-
The determination of glutamine with flow-injection chemiluminescence detection and mechanism study.Luminescence. 2010 Jan-Feb;25(1):50-4. doi: 10.1002/bio.1143. Luminescence. 2010. PMID: 19630088
-
Determination of trace amounts of dopamine by flow-injection analysis coupled with luminol-Ag(III) complex chemiluminescence detection.Luminescence. 2011 Mar-Apr;26(2):93-100. doi: 10.1002/bio.1189. Luminescence. 2011. PMID: 20446341
-
Determination of dopamine by flow-injection analysis coupled with luminol-hexacyanoferrate(III) chemiluminescence detection.J Pharm Biomed Anal. 2004 Sep 21;36(1):219-23. doi: 10.1016/j.jpba.2004.05.009. J Pharm Biomed Anal. 2004. PMID: 15351069
-
[New advances in liquid chromatography-chemiluminescence detection].Se Pu. 1997 Jul;15(4):296-300. Se Pu. 1997. PMID: 15739459 Review. Chinese.
-
An overview of qualimetric strategies for optimisation and calibration in pharmaceutical analysis using flow injection techniques.Anal Bioanal Chem. 2003 Nov;377(5):863-74. doi: 10.1007/s00216-003-2142-4. Epub 2003 Aug 28. Anal Bioanal Chem. 2003. PMID: 14564437 Review.
Cited by
-
Determination of Exogenous Adrenaline Levels in Patients Undergoing Cardiopulmonary Resuscitation.ACS Omega. 2023 May 25;8(22):19425-19432. doi: 10.1021/acsomega.3c00555. eCollection 2023 Jun 6. ACS Omega. 2023. PMID: 37305245 Free PMC article.
-
Thermoelectric, Electrochemical, & Dielectric Properties of Four ZnO Nanostructures.Materials (Basel). 2022 Dec 9;15(24):8816. doi: 10.3390/ma15248816. Materials (Basel). 2022. PMID: 36556622 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical