Bottom-up nanotechnology: the human nephron filter
- PMID: 20017838
- DOI: 10.1111/j.1525-139X.2009.00671.x
Bottom-up nanotechnology: the human nephron filter
Abstract
Over one million patients worldwide have end-stage renal disease and require dialysis or kidney transplantation. Despite the availability of these forms of renal replacement therapy for nearly four decades, mortality and morbidity are high and patients often have a poor quality of life. We have developed a human nephron filter (HNF) utilizing bottom-up nanotechnology that would eventually make feasible a continuously functioning, wearable or implantable artificial kidney. The device consists of two membranes operating in series within one device cartridge. The first membrane mimics the function of the glomerulus, using convective transport to generate a plasma ultra filtrate, which contains all solutes approaching the molecular weight of albumin. The second membrane mimics the function of the renal tubules, selectively reclaiming designated solutes to maintain body homeostasis. No dialysis solution is used in this device. The HNF has been computer modeled, and operating 12 hour per day, 7 days per week the HNF provides the equivalent of 30 ml/min glomerular filtration rate (compared to half that amount for conventional thrice-weekly hemodialysis). The HNF system, by eliminating dialysate and utilizing a novel membrane system created through applied nanotechnology, represents a breakthrough in renal replacement therapy based on the functioning of native kidneys. The enhanced solute removal and wearable design should substantially improve patient outcomes and quality of life.
Similar articles
-
Continuously functioning artificial nephron system: the promise of nanotechnology.Hemodial Int. 2005 Jul;9(3):210-7. doi: 10.1111/j.1492-7535.2005.01135.x. Hemodial Int. 2005. PMID: 16191071
-
The human nephron filter: toward a continuously functioning, implantable artificial nephron system.Blood Purif. 2005;23(4):269-74. doi: 10.1159/000085882. Epub 2005 May 20. Blood Purif. 2005. PMID: 15908745
-
The future of renal replacement therapy.Adv Chronic Kidney Dis. 2007 Jul;14(3):249-55. doi: 10.1053/j.ackd.2007.05.001. Adv Chronic Kidney Dis. 2007. PMID: 17603978 Review.
-
[Renal replacement therapy by hemodialysis: an overview].Nephrol Ther. 2009 Jul;5(4):306-12. doi: 10.1016/j.nephro.2009.03.001. Epub 2009 May 28. Nephrol Ther. 2009. PMID: 19481513 Review. French.
-
Development of continuous implantable renal replacement: past and future.Transl Res. 2007 Dec;150(6):327-36. doi: 10.1016/j.trsl.2007.06.001. Epub 2007 Jul 2. Transl Res. 2007. PMID: 18022594 Review.
Cited by
-
Enhanced H-filter based on Fåhræus-Lindqvist effect for efficient and robust dialysis without membrane.Biomicrofluidics. 2015 Jul 31;9(4):044112. doi: 10.1063/1.4927574. eCollection 2015 Jul. Biomicrofluidics. 2015. PMID: 26339313 Free PMC article.
-
Permselectivity Replication of Artificial Glomerular Basement Membranes in Nanoporous Collagen Multilayers.J Phys Chem Lett. 2011 Dec;2(16):2067-2072. doi: 10.1021/jz200880c. J Phys Chem Lett. 2011. PMID: 22200004 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical