Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2010 Feb 1;878(3-4):481-6.
doi: 10.1016/j.jchromb.2009.12.005. Epub 2009 Dec 16.

Enantiomeric determination of tramadol and O-desmethyltramadol in human plasma by fast liquid chromatographic technique coupled with mass spectrometric detection

Affiliations
Clinical Trial

Enantiomeric determination of tramadol and O-desmethyltramadol in human plasma by fast liquid chromatographic technique coupled with mass spectrometric detection

Lukás Chytil et al. J Chromatogr B Analyt Technol Biomed Life Sci. .

Abstract

A rapid and sensitive method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) for enantiomeric determination of tramadol and its primary phase metabolite O-desmethyltramadol in human plasma has been developed. Tramadol hydrochloride-(13)C, d(3), was used as an isotopic labeled internal standard for quantification. The method involves a simple solid phase extraction. The analytes and internal standard were separated on Lux Cellulose-2 packed with cellulose tris(3-chloro-4-methylphenylcarbamate) using isocratic elution with hexane/isopropanol/diethylamine (90:10:0.1, v/v/v) at a flow rate of 1.3 mL/min. The APCI positive ionization mass spectrometry was used with multiple reaction monitoring of the transitions at m/z 264.2-->58.2 for tramadol, m/z 250.1-->58.2 for O-desmethyltramadol and m/z 268.2-->58.2 for internal standard. Linearity was achieved between 1-800 ng/mL and 1-400 ng/mL (R(2) > or = 0.999) for each enantiomer of tramadol and O-desmethyltramadol, respectively. Intra-day accuracies ranged among 98.2-102.8%, 97.1-109.1% and 97.4-102.9% at the lower, intermediate, and high concentration for all analytes, respectively. Inter-day accuracies ranged among 95.5-104.1%, 99.2-104.7%, and 94.2-105.6% at the lower, intermediate, and high concentration for all analytes, respectively. This assay was successfully used to determine the concentration of enantiomers of tramadol and O-desmethyltramadol in a pharmacogenetic study.

PubMed Disclaimer

Publication types

LinkOut - more resources