Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2010 Jan;254(1):163-9.
doi: 10.1148/radiol.09090369. Epub 2009 Dec 17.

Body size indexes for optimizing iodine dose for aortic and hepatic enhancement at multidetector CT: comparison of total body weight, lean body weight, and blood volume

Affiliations
Randomized Controlled Trial

Body size indexes for optimizing iodine dose for aortic and hepatic enhancement at multidetector CT: comparison of total body weight, lean body weight, and blood volume

Hiroshi Kondo et al. Radiology. 2010 Jan.

Abstract

Purpose: To evaluate and compare total body weight (TBW), lean body weight (LBW), and estimated blood volume (BV) for the adjustment of the iodine dose required for contrast material-enhanced multidetector computed tomography (CT) of the aorta and liver.

Materials and methods: Institutional review committee approval and written informed consent were obtained. One hundred twenty patients (54 men, 66 women; mean age, 64.1 years; range, 19-88 years) who underwent multidetector CT of the upper abdomen were randomized into three groups of 40 patients each: (a) TBW group (0.6 g of iodine per kilogram of TBW), (b) LBW group (0.821 g of iodine per kilogram of LBW), and (c) BV group (men, 8.6 g of iodine per liter of BV; women, 9.9 g of iodine per liter of BV). Change in CT number between unenhanced and contrast-enhanced images per gram of iodine and maximum hepatic enhancement (MHE) adjusted for iodine dose were examined for correlation with TBW, LBW, and BV by using linear regression analysis.

Results: In the portal venous phase, correlation coefficients for the correlation of change in CT number per gram of iodine with TBW for the aorta and liver were -0.71 and -0.79, respectively, in the TBW group; -0.80 and -0.86, respectively, in the LBW group; and -0.68 and -0.66, respectively, in the BV group. In the liver, they were marginally higher in the LBW group than in the BV group (P = .03). Adjusted MHE remained constant at 77.9 HU +/- 10.2 (standard deviation) in the LBW group with respect to TBW, but it increased in the TBW (r = 0.80, P < .001) and BV (r = 0.70, P < .001) groups as TBW increased.

Conclusion: When LBW, rather than TBW or BV, is used, the iodine dose required to achieve consistent hepatic enhancement may be estimated more precisely and with reduced patient-to-patient variability.

PubMed Disclaimer

Publication types