The mechanical effects of different levels of cement penetration at the cement-bone interface
- PMID: 20022010
- PMCID: PMC2849873
- DOI: 10.1016/j.jbiomech.2009.11.033
The mechanical effects of different levels of cement penetration at the cement-bone interface
Abstract
The mechanical effects of varying the depth of cement penetration in the cement-bone interface were investigated using finite element analysis (FEA) and validated using companion experimental data. Two FEA models of the cement-bone interface were created from micro-computed tomography data and the penetration of cement into the bone was varied over six levels each. The FEA models, consisting of the interdigitated cement-bone constructs with friction between cement and bone, were loaded to failure in tension and in shear. The cement and bone elements had provision for crack formation due to excessive stress. The interfacial strength showed a strong relationship with the average interdigitation (r(2)=0.97 and r(2)=0.93 in tension and shear, respectively). Also, the interface strength was strongly related with the contact area (r(2)=0.98 and r(2)=0.95 in tension and shear, respectively). The FEA results compared favorably to the stiffness-strength relationships determined experimentally. Overall, the cement-bone interface was 2.5 times stronger in shear than in tension and 1.15 times stiffer in tension than in shear, independent of the average interdigitation. More cracks occurred in the cement than in the bone, independent of the average interdigitation, consistent with the experimental results. In addition, more cracks were generated in shear than in tension. In conclusion, achieving and maintaining maximal infiltration of cement into the bone to obtain large interdigitation and contact area is key to optimizing the interfacial strength.
Copyright 2009 Elsevier Ltd. All rights reserved.
Conflict of interest statement
None of the authors have financial or personal relationships with other people or organizations that could inappropriately influence or bias the currently presented work.
Figures









References
-
- Askew MJ, Steege JW, Lewis JL, Ranieri JR, Wixson RL. Effect of cement pressure and bone strength on polymethylmethacrylate fixation. J Orthop Res. 1984;1:412–420. - PubMed
-
- Bean DJ, Convery FR, Woo SL, Lieber RL. Regional variation in shear strength of the bone-polymethylmethacrylate interface. J Arthroplasty. 1987;2:293–298. - PubMed
-
- Berry DJ. Cemented femoral stems: what matters most. J Arthroplasty. 2004;19:83–84. - PubMed
-
- Bugbee WD, Barrera DL, Lee AC, Convery FR. Variations in shear strength of the bone-cement interface in the proximal femur. Trans Orthop Res Soc. 1992;17:22.
-
- Freeman MA, Bradley GW, Revell PA. Observations upon the interface between bone and polymethylmethacrylate cement. J Bone Joint Surg Br. 1982;64:489–493. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources