The covalent immobilization of heparin to pulsed-plasma polymeric allylamine films on 316L stainless steel and the resulting effects on hemocompatibility
- PMID: 20022107
- DOI: 10.1016/j.biomaterials.2009.11.091
The covalent immobilization of heparin to pulsed-plasma polymeric allylamine films on 316L stainless steel and the resulting effects on hemocompatibility
Abstract
For an improved hemocompatibility of 316L stainless steel (SS), we develop a facile and effective approach to fabricating a pulsed-plasma polymeric allylamine (P-PPAm) film that possesses a high cross-linking degree and a high density of amine groups, which is used for subsequent bonding of heparin. The P-PPAm film as a stent coating shows good resistance to the deformation behavior of compression and expansion of a stent. Using deionized water as an aging medium, it is demonstrated that the heparin-immobilized P-PPAm (Hep-P-PPAm) surface has a good retention of heparin. The systematic in vitro hemocompatibility evaluation reveals lower platelet adhesion, platelet activation and fibrinogen activation on the Hep-P-PPAm surface, and the activated partial thromboplastin time prolongs for about 15 s compared with 316L SS. The P-PPAm surface significantly promotes adhesion and proliferation of endothelial cells (ECs). For the Hep-P-PPAm, although EC adhesion and proliferation is slightly suppressed initially, after cultivation for 3 days, the growth behavior of ECs is remarkably improved over 316L SS. In vivo results indicate that the Hep-P-PPAm surface successfully restrain thrombus formation by growing a homogeneous and intact shuttle-like endothelium on its surface. The Hep-P-PPAm modified 316L SS shows a promising application for vascular devices.
Copyright (c) 2009 Elsevier Ltd. All rights reserved.
Similar articles
-
Mussel-inspired one-step adherent coating rich in amine groups for covalent immobilization of heparin: hemocompatibility, growth behaviors of vascular cells, and tissue response.ACS Appl Mater Interfaces. 2014 Aug 27;6(16):14608-20. doi: 10.1021/am503925r. Epub 2014 Aug 18. ACS Appl Mater Interfaces. 2014. PMID: 25105346
-
The effect of coimmobilizing heparin and fibronectin on titanium on hemocompatibility and endothelialization.Biomaterials. 2011 Jul;32(21):4691-703. doi: 10.1016/j.biomaterials.2011.03.025. Epub 2011 Apr 3. Biomaterials. 2011. PMID: 21463893
-
Construction and hemocompatibility study of highly bioactive heparin-functionalized surface.J Biomed Mater Res A. 2012 Nov;100(11):3124-33. doi: 10.1002/jbm.a.34247. Epub 2012 Jul 20. J Biomed Mater Res A. 2012. PMID: 22815121
-
Surface modification of stainless steel for biomedical applications: Revisiting a century-old material.Mater Sci Eng C Mater Biol Appl. 2018 Dec 1;93:1073-1089. doi: 10.1016/j.msec.2018.08.049. Epub 2018 Aug 24. Mater Sci Eng C Mater Biol Appl. 2018. PMID: 30274039 Review.
-
[Study and evaluation on hemocompatibility of biomaterials].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2009 Oct;26(5):1162-6. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2009. PMID: 19947512 Review. Chinese.
Cited by
-
Heparin-functionalized polymer graft surface eluting MK2 inhibitory peptide to improve hemocompatibility and anti-neointimal activity.J Control Release. 2017 Nov 28;266:321-330. doi: 10.1016/j.jconrel.2017.10.002. Epub 2017 Oct 4. J Control Release. 2017. PMID: 28987880 Free PMC article.
-
Microfabrication and nanotechnology in stent design.Wiley Interdiscip Rev Nanomed Nanobiotechnol. 2011 May-Jun;3(3):256-68. doi: 10.1002/wnan.123. Epub 2011 Jan 31. Wiley Interdiscip Rev Nanomed Nanobiotechnol. 2011. PMID: 21462356 Free PMC article. Review.
-
Dextran grafting on PTFE surface for cardiovascular applications.Biomatter. 2014;4:e28805. doi: 10.4161/biom.28805. Biomatter. 2014. PMID: 25482414 Free PMC article.
-
Plasma torch toothbrush a new insight in fear free dentisry.J Clin Diagn Res. 2014 Jun;8(6):ZE07-10. doi: 10.7860/JCDR/2014/8815.4516. Epub 2014 Jun 20. J Clin Diagn Res. 2014. PMID: 25121075 Free PMC article. Review.
-
Constructing bio-layer of heparin and type IV collagen on titanium surface for improving its endothelialization and blood compatibility.J Mater Sci Mater Med. 2016 Apr;27(4):81. doi: 10.1007/s10856-016-5693-6. Epub 2016 Mar 2. J Mater Sci Mater Med. 2016. PMID: 26936367
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical