The evolution of real-time PCR machines to real-time PCR chips
- PMID: 20022485
- DOI: 10.1016/j.bios.2009.11.021
The evolution of real-time PCR machines to real-time PCR chips
Abstract
Development of Micro-Electro-Mechanical Systems (MEMS) technology has recently allowed the migration of real-time polymerase chain reaction (PCR) machines to lab-on-a-chip systems. The miniaturization of biological instruments has been studied extensively, with several prototypes constructed and tested. In this study, the lab-on-a-chip system is evaluated; its DNA quantification is estimated by theorems, and the specifications of proposed chip prototypes are compared with the original machines. The analysis results suggest five hypotheses. Using experiments and the data collected from published papers, these hypotheses were either verified or rejected, and the advantages and shortcomings of real-time PCR chips were identified. The proven advantages of the lab-on-a-chip system are its compact size, low sample volume to nano-liter, and short analysis time-less than 10s to complete one PCR cycle and 370 s for completing the whole quantification process. However, the detection limits, quantification uncertainties, and melting analysis ability of the chip prototypes are at best comparable to, and perhaps worse than, those of commercial instruments. Real-time PCR chips are not perfectly accurate diagnostic tools for a laboratory but they have advantages over traditional techniques for point-of-care testing.
(c) 2009 Elsevier B.V. All rights reserved.
Similar articles
-
Real time PCR on disposable PDMS chip with a miniaturized thermal cycler.Biomed Microdevices. 2005 Dec;7(4):273-9. doi: 10.1007/s10544-005-6069-8. Biomed Microdevices. 2005. PMID: 16404505
-
PCR microfluidic devices for DNA amplification.Biotechnol Adv. 2006 May-Jun;24(3):243-84. doi: 10.1016/j.biotechadv.2005.10.002. Epub 2005 Dec 2. Biotechnol Adv. 2006. PMID: 16326063 Review.
-
Electrical microarrays for highly sensitive detection of multiplex PCR products from biological agents.Biosens Bioelectron. 2009 Feb 15;24(6):1737-43. doi: 10.1016/j.bios.2008.09.003. Epub 2008 Sep 12. Biosens Bioelectron. 2009. PMID: 18954971
-
[Quantitative PCR in the diagnosis of Leishmania].Parassitologia. 2004 Jun;46(1-2):163-7. Parassitologia. 2004. PMID: 15305709 Review. Italian.
-
On-chip, real-time, single-copy polymerase chain reaction in picoliter droplets.Anal Chem. 2007 Nov 15;79(22):8471-5. doi: 10.1021/ac701809w. Epub 2007 Oct 11. Anal Chem. 2007. PMID: 17929880
Cited by
-
Miniaturized technology for protein and nucleic acid point-of-care testing.Transl Res. 2012 Nov;160(5):332-45. doi: 10.1016/j.trsl.2012.02.012. Epub 2012 Mar 11. Transl Res. 2012. PMID: 22683416 Free PMC article. Review.
-
Q3: A Compact Device for Quick, High Precision qPCR.Sensors (Basel). 2018 Aug 7;18(8):2583. doi: 10.3390/s18082583. Sensors (Basel). 2018. PMID: 30087266 Free PMC article.
-
Fusing MEMS technology with lab-on-chip: nanoliter-scale silicon microcavity arrays for digital DNA quantification and multiplex testing.Microsyst Nanoeng. 2020 Oct 5;6:82. doi: 10.1038/s41378-020-00187-1. eCollection 2020. Microsyst Nanoeng. 2020. PMID: 34567692 Free PMC article.
-
2021 Patient Preferences for Point of Care Testing Survey: More Acceptance and Less Concern.J Appl Lab Med. 2022 Oct 29;7(6):1302-1310. doi: 10.1093/jalm/jfac070. J Appl Lab Med. 2022. PMID: 36093730 Free PMC article.
-
Molecular markers and mechanisms of stroke: RNA studies of blood in animals and humans.J Cereb Blood Flow Metab. 2011 Jul;31(7):1513-31. doi: 10.1038/jcbfm.2011.45. Epub 2011 Apr 20. J Cereb Blood Flow Metab. 2011. PMID: 21505474 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous