The evolution of chemotaxis assays from static models to physiologically relevant platforms
- PMID: 20023801
- DOI: 10.1039/b814567a
The evolution of chemotaxis assays from static models to physiologically relevant platforms
Abstract
The role of chemotactic gradients in the immunological response is an area which elicits a lot of attention due to its impact on the outcome of the inflammatory process. Consequently there are numerous standard in vitro designs which attempt to mimic chemotactic gradients, albeit in static conditions, and with no control over the concentration of the chemokine gradient. In recent times the design of the standard chemotaxis assay has incorporated modern microfluidic platforms, computer controlled flow devices and cell tracking software. Assays under fluid flow which use biochips have provided data which highlight the importance of shear stress on cell attachment and migration towards a chemokine gradient. However, the in vivo environment is far more complex in comparison to conventional cell assay chambers. The designs of biochips are therefore in constant flux as advances in technology permit ever greater imitations of in vivo conditions. Researchers are focused on designing a generation of new biochips and enhancing the physiological relevance of the current assays. The challenge is to combine a shear flow with a 3D scaffold containing the endothelial layer and permitting a natural diffusion of chemokines through a tissue-like basal matrix. Here we review the latest range of chemotaxis assays and assess the innovative features of their designs which enable them to better imitate the in vivo environment. We also present some alternative designs that were initially employed in tissue engineering which could potentially be used in the establishment of novel chemotaxis assays.
Similar articles
-
Chapter 15. A microfluidics-based method for chemoattractant gradients.Methods Enzymol. 2009;461:333-47. doi: 10.1016/S0076-6879(09)05415-9. Methods Enzymol. 2009. PMID: 19480926
-
Vascular mimetics based on microfluidics for imaging the leukocyte--endothelial inflammatory response.Lab Chip. 2007 Apr;7(4):448-56. doi: 10.1039/b617915k. Epub 2007 Jan 23. Lab Chip. 2007. PMID: 17389960
-
Targeting the leukocyte activation cascade: getting to the site of inflammation using microfabricated assays.Lab Chip. 2012 Jun 21;12(12):2255-64. doi: 10.1039/c2lc21078a. Epub 2012 Mar 22. Lab Chip. 2012. PMID: 22437145
-
Leucocyte recruitment under fluid shear: mechanical and molecular regulation within the inflammatory synapse.Clin Exp Pharmacol Physiol. 2009 Feb;36(2):217-24. doi: 10.1111/j.1440-1681.2008.05083.x. Epub 2008 Nov 7. Clin Exp Pharmacol Physiol. 2009. PMID: 19018799 Review.
-
Novel chemokine functions in lymphocyte migration through vascular endothelium under shear flow.J Leukoc Biol. 2001 Jun;69(6):860-6. J Leukoc Biol. 2001. PMID: 11404368 Review.
Cited by
-
A new chemotaxis device for cell migration studies.Integr Biol (Camb). 2010 Nov;2(11-12):696-706. doi: 10.1039/c0ib00044b. Epub 2010 Oct 12. Integr Biol (Camb). 2010. PMID: 20938544 Free PMC article.
-
Microfluidic technologies for temporal perturbations of chemotaxis.Annu Rev Biomed Eng. 2010 Aug 15;12:259-84. doi: 10.1146/annurev-bioeng-070909-105241. Annu Rev Biomed Eng. 2010. PMID: 20450351 Free PMC article. Review.
-
Bioreactor engineering of stem cell environments.Biotechnol Adv. 2013 Nov 15;31(7):1020-31. doi: 10.1016/j.biotechadv.2013.03.007. Epub 2013 Mar 24. Biotechnol Adv. 2013. PMID: 23531529 Free PMC article. Review.
-
Advanced 2D/3D cell migration assay for faster evaluation of chemotaxis of slow-moving cells.PLoS One. 2019 Jul 17;14(7):e0219708. doi: 10.1371/journal.pone.0219708. eCollection 2019. PLoS One. 2019. PMID: 31314801 Free PMC article.
-
On-chip evaluation of neutrophil activation and neutrophil-endothelial cell interaction during neutrophil chemotaxis.Anal Chem. 2013 Nov 19;85(22):10787-96. doi: 10.1021/ac4020098. Epub 2013 Oct 28. Anal Chem. 2013. PMID: 24127752 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources