Fetal autonomic response to severe acidaemia during labour
- PMID: 20025619
- DOI: 10.1111/j.1471-0528.2009.02456.x
Fetal autonomic response to severe acidaemia during labour
Abstract
Objective: Spectral analysis of heart-rate variability is used to monitor autonomic nervous system fluctuations. The low-frequency component is associated with sympathetic and parasympathetic modulation and the high-frequency component is associated with parasympathetic modulation. The objective was to study whether changes in low-frequency or high-frequency power of heart-rate variability occur in case of fetal distress.
Design: Case-control study.
Setting: Obstetric unit of a tertiary-care teaching hospital.
Population: Twenty healthy human fetuses during labour at term of which ten had an umbilical artery pH < 7.05 (cases), and ten had an arterial pH > 7.20 (controls) after birth.
Methods: Spectral information about fetal beat-to-beat heart rate, calculated from direct fetal electrocardiogram registrations, was obtained by using a short-time Fourier transform.
Main outcome measures: Absolute power and normalised power in the low-frequency and high-frequency bands.
Results: No differences were found between fetuses with and without acidaemia in absolute low or high frequency power (P = 0.2 and P = 0.3, respectively). During the last 30 minutes of labour, acidaemic fetuses had significantly increased normalised low-frequency power (P = 0.01) and decreased normalised high-frequency power (P = 0.03) compared with non-acidaemic fetuses. These differences were not observed from 3 to 2 hours before birth (P = 0.7 and P = 0.9, respectively).
Conclusion: The autonomic nervous system of human fetuses at term responds adequately to severe stress during labour. Normalised low and high frequency power of heart-rate variability might be able to discriminate between normal and abnormal fetal condition.
Similar articles
-
Marked fetal acidosis and specific changes in power spectrum analysis of fetal heart rate variability recorded during the last hour of labour.BJOG. 2005 Apr;112(4):418-23. doi: 10.1111/j.1471-0528.2004.00454.x. BJOG. 2005. PMID: 15777438
-
Power spectrum analysis of fetal heart rate variability at near term and post term gestation during active sleep and quiet sleep.Early Hum Dev. 2009 Dec;85(12):795-8. doi: 10.1016/j.earlhumdev.2009.11.001. Early Hum Dev. 2009. PMID: 19931326
-
Specific change in spectral power of fetal heart rate variability related to fetal acidemia during labor: comparison between preterm and term fetuses.Early Hum Dev. 2012 Apr;88(4):203-7. doi: 10.1016/j.earlhumdev.2011.08.007. Epub 2011 Sep 17. Early Hum Dev. 2012. PMID: 21930353
-
[Abnormal fetal heart rate patterns associated with different labour managements and intrauterine resuscitation techniques].J Gynecol Obstet Biol Reprod (Paris). 2008 Feb;37 Suppl 1:S56-64. doi: 10.1016/j.jgyn.2007.11.011. Epub 2008 Jan 9. J Gynecol Obstet Biol Reprod (Paris). 2008. PMID: 18187267 Review. French.
-
Intermittent auscultation of fetal heart rate during labour - a widely accepted technique for low risk pregnancies: but are the current national guidelines robust and practical?J Obstet Gynaecol. 2010;30(6):537-40. doi: 10.3109/01443615.2010.484108. J Obstet Gynaecol. 2010. PMID: 20701496 Review.
Cited by
-
Is short-term-variation of fetal-heart-rate a better predictor of fetal acidaemia in labour? A feasibility study.PLoS One. 2020 Aug 3;15(8):e0236982. doi: 10.1371/journal.pone.0236982. eCollection 2020. PLoS One. 2020. PMID: 32745099 Free PMC article.
-
The Critical Role of the Central Autonomic Nervous System in Fetal-Neonatal Transition.Semin Pediatr Neurol. 2018 Dec;28:29-37. doi: 10.1016/j.spen.2018.05.004. Epub 2018 Jun 20. Semin Pediatr Neurol. 2018. PMID: 30522725 Free PMC article. Review.
-
Relation of fetal heart rate signals with unassignable baseline to poor neonatal state at birth.Med Biol Eng Comput. 2012 Jul;50(7):717-25. doi: 10.1007/s11517-012-0923-7. Epub 2012 Jun 8. Med Biol Eng Comput. 2012. PMID: 22678597
-
Towards better reliability in fetal heart rate variability using time domain and spectral domain analyses. A new method for assessing fetal neurological state?PLoS One. 2022 Mar 1;17(3):e0263272. doi: 10.1371/journal.pone.0263272. eCollection 2022. PLoS One. 2022. PMID: 35231034 Free PMC article.
-
Systematic Review of Intrapartum Fetal Heart Rate Spectral Analysis and an Application in the Detection of Fetal Acidemia.Front Pediatr. 2021 Aug 2;9:661400. doi: 10.3389/fped.2021.661400. eCollection 2021. Front Pediatr. 2021. PMID: 34408993 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources