Noise and baseline wandering suppression of ECG signals by morphological filter
- PMID: 20028196
- DOI: 10.3109/03091900903336886
Noise and baseline wandering suppression of ECG signals by morphological filter
Abstract
Electrocardiogram (ECG) signals describe the electrical activity of the heart, and are universally by physicists in the diagnosis of cardiac pathologies. However, during the acquisition of ECGs they are often contaminated with different sources of noise, making interpretation difficult. Different techniques have been used to filter the ECG signal, in order to optimize the signal to noise ratio (S/N). In this paper, an approach based on morphological filtering is developed in order to filter the ECG. Morphological filtering is concerned with the detection of the ECG morphology, therefore allowing the suppression of noises and particularly baseline wandering. The implemented filter is evaluated using signals taken from the MIT-BIH ECG universal database. The results show that the performance of this filter is good compared with other filtering techniques.
Similar articles
-
[ECG signal preprocessing based on morphological filtering].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2011 Apr;28(2):365-70. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2011. PMID: 21604503 Chinese.
-
Alexander fractional differential window filter for ECG denoising.Australas Phys Eng Sci Med. 2018 Jun;41(2):519-539. doi: 10.1007/s13246-018-0642-y. Epub 2018 Apr 23. Australas Phys Eng Sci Med. 2018. PMID: 29687436
-
An adaptive Kalman filter for ECG signal enhancement.IEEE Trans Biomed Eng. 2011 Apr;58(4):1094-103. doi: 10.1109/TBME.2010.2099229. Epub 2010 Dec 13. IEEE Trans Biomed Eng. 2011. PMID: 21156383
-
A review of electrocardiogram filtering.J Electrocardiol. 2010 Nov-Dec;43(6):486-96. doi: 10.1016/j.jelectrocard.2010.07.007. Epub 2010 Sep 18. J Electrocardiol. 2010. PMID: 20851409 Review.
-
A review of the performance of artifact filtering algorithms for cardiopulmonary resuscitation.J Healthc Eng. 2013;4(2):185-202. doi: 10.1260/2040-2295.4.2.185. J Healthc Eng. 2013. PMID: 23778011 Review.
Cited by
-
Electrocardiogram Baseline Wander Suppression Based on the Combination of Morphological and Wavelet Transformation Based Filtering.Comput Math Methods Med. 2019 Mar 3;2019:7196156. doi: 10.1155/2019/7196156. eCollection 2019. Comput Math Methods Med. 2019. PMID: 30944579 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources