Dual-source dual-energy MDCT of pancreatic adenocarcinoma: initial observations with data generated at 80 kVp and at simulated weighted-average 120 kVp
- PMID: 20028887
- DOI: 10.2214/AJR.09.2737
Dual-source dual-energy MDCT of pancreatic adenocarcinoma: initial observations with data generated at 80 kVp and at simulated weighted-average 120 kVp
Abstract
Objective: The purpose of this study was to determine whether the conspicuity of malignant tumors of the pancreas at dual-source dual-energy CT is better with 80-kVp acquisition than with 120-kVp acquisition simulated with a weighted average.
Materials and methods: Fifteen patients with pancreatic adenocarcinoma underwent contrast-enhanced dual-source dual-energy CT. The abdominal diameter of all patients was 35 cm or less. Data were reconstructed as a weighted average of the 140- and 80-kVp acquisitions, simulating 120 kVp, and as a pure 80-kVp data set. A region-of-interest cursor was placed within the tumor and the adjacent normal parenchyma, and attenuation differences and contrast-to-noise ratios were calculated for pancreatic tumors at 80 kVp and with the weighted-average acquisition. The 80-kVp and weighted-average images were subjectively compared in terms of lesion conspicuity, image quality, and duct visualization. An exact Wilcoxon's matched pairs signed rank test was used to test whether differences in attenuation, contrast-to-noise ratio, and subjective assessment were greater at 80 kVp.
Results: The mean difference in attenuation for each pancreatic tumor and adjacent portion of normal pancreas was 83.27+/-29.56 (SD) HU at 80 kVp and 49.40+/-23.00 HU at weighted-average 120 kVp. Adenocarcinoma attenuation differences were significantly greater at 80 kVp than at 120 kVp (p=0.00006). Contrast-to-noise ratio was significantly higher at 80 kVp than at 120 kVp (p=0.00147). Subjective analysis showed lesion conspicuity (p=0.001) and duct visualization (p=0.0156) were significantly better on the 80-kVp images.
Conclusion: At portal venous phase dual-source dual-energy CT, the conspicuity of malignant tumors of the pancreas is greater at 80 kVp than with weighted-average acquisition.
Similar articles
-
Dual source dual energy MDCT: comparison of 80 kVp and weighted average 120 kVp data for conspicuity of hypo-vascular liver metastases.Invest Radiol. 2010 Jul;45(7):413-8. doi: 10.1097/RLI.0b013e3181dfda78. Invest Radiol. 2010. PMID: 20458250
-
Split-bolus spectral multidetector CT of the pancreas: assessment of radiation dose and tumor conspicuity.Radiology. 2013 Oct;269(1):139-48. doi: 10.1148/radiol.13121409. Epub 2013 May 14. Radiology. 2013. PMID: 23674791 Clinical Trial.
-
Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: optimization of energy level viewing significantly increases lesion contrast.Clin Radiol. 2013 Feb;68(2):148-54. doi: 10.1016/j.crad.2012.06.108. Epub 2012 Aug 11. Clin Radiol. 2013. PMID: 22889459
-
Dual-energy computed tomography imaging of the aorta.J Thorac Imaging. 2010 Nov;25(4):289-300. doi: 10.1097/RTI.0b013e3181dc2b4c. J Thorac Imaging. 2010. PMID: 21042067 Review.
-
Dual-energy and low-kVp CT in the abdomen.AJR Am J Roentgenol. 2009 Jul;193(1):47-54. doi: 10.2214/AJR.09.2592. AJR Am J Roentgenol. 2009. PMID: 19542394 Free PMC article. Review.
Cited by
-
Low-tube-voltage 80-kVp neck CT: evaluation of diagnostic accuracy and interobserver agreement.AJNR Am J Neuroradiol. 2014 Dec;35(12):2376-81. doi: 10.3174/ajnr.A4052. Epub 2014 Aug 7. AJNR Am J Neuroradiol. 2014. PMID: 25104285 Free PMC article.
-
Utility of Dual-Energy Computed Tomography in Clinical Conundra.Diagnostics (Basel). 2024 Apr 7;14(7):775. doi: 10.3390/diagnostics14070775. Diagnostics (Basel). 2024. PMID: 38611688 Free PMC article. Review.
-
"Sweet spot" for endoleak detection: optimizing contrast to noise using low keV reconstructions from fast-switch kVp dual-energy CT.J Comput Assist Tomogr. 2012 Jan-Feb;36(1):83-7. doi: 10.1097/RCT.0b013e31824258cb. J Comput Assist Tomogr. 2012. PMID: 22261775 Free PMC article.
-
Dual-source, dual-energy multidetector CT for the evaluation of pancreatic tumours.Br J Radiol. 2012 Oct;85(1018):e891-8. doi: 10.1259/bjr/26129418. Br J Radiol. 2012. PMID: 22972978 Free PMC article.
-
Performance of dual-layer spectrum CT virtual monoenergetic images to assess early rectal adenocarcinoma T-stage: comparison with MR.Insights Imaging. 2024 Jan 17;15(1):11. doi: 10.1186/s13244-023-01593-5. Insights Imaging. 2024. PMID: 38228903 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical