Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Feb;103(2):1048-56.
doi: 10.1152/jn.00881.2009. Epub 2009 Dec 23.

Frequency-specific modulation of vestibular-evoked sway responses in humans

Affiliations
Free article

Frequency-specific modulation of vestibular-evoked sway responses in humans

Christopher J Dakin et al. J Neurophysiol. 2010 Feb.
Free article

Abstract

Galvanic vestibular stimulation (GVS) results in characteristic muscle and whole-body responses in humans maintaining standing balance. However, the relationship between these two vestibular-evoked responses remains elusive. This study seeks to determine whether mechanical filtering from conversion of lower-limb muscle activity to body sway, during standing balance, can be used to attenuate sway while maintaining biphasic lower-limb muscle responses using frequency-limited stochastic vestibular stimulation (SVS). We hypothesized that SVS deprived of frequencies <2 Hz would evoke biphasic muscle responses with minimal whole-body sway due to mechanical filtering of the higher-frequency muscle responses. Subjects were exposed to five stimulus bandwidths: two meant to induce sway responses (0-1 and 0-2 Hz) and three to dissociate vestibular-evoked muscle responses from whole-body sway (0-25, 1-25, and 2-25 Hz). Two main results emerged: 1) SVS-related sway was attenuated when frequencies <2 Hz were excluded, whereas multiphasic muscle and force responses were retained; and 2) the gain of the estimated transfer functions exhibited successive low-pass filtering of vestibular stimuli during conversion to muscle activity, anteroposterior (AP) moment, and sway. This successive low-pass filtering limited the transfer of signal power to frequencies <20 Hz in muscle activity, <5 Hz in AP moment, and <2 Hz in AP trunk sway. Consequently, the present results show that SVS delivered at frequencies >2 Hz to standing humans do not cause a destabilizing whole-body sway response but are associated with the typical biphasic lower-limb muscle responses.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources