Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Oct;69(4):855-60.
doi: 10.1097/TA.0b013e3181c4526f.

Measurable outcomes of quality improvement using a daily quality rounds checklist: one-year analysis in a trauma intensive care unit with sustained ventilator-associated pneumonia reduction

Affiliations

Measurable outcomes of quality improvement using a daily quality rounds checklist: one-year analysis in a trauma intensive care unit with sustained ventilator-associated pneumonia reduction

Joseph Dubose et al. J Trauma. 2010 Oct.

Abstract

Background: We have previously demonstrated that the use of a daily "Quality Rounds Checklist" (QRC) can increase compliance with evidence-based prophylactic measures and decrease complications in a busy trauma intensive care unit (ICU) over a 3-month period. This study was designed to determine the sustainability of QRC use over 1 year and examine the relationship between compliance and outcome improvement.

Methods: A prospective before-after design was used to examine the effectiveness of the QRC tool in documenting compliance with 16 prophylactic measures for ventilator-associated pneumonia (VAP), deep venous thrombosis, pulmonary embolism, catheter-related bloodstream infection, and other ICU complications. The QRC was implemented on a daily basis for a 1-year period by the ICU fellow on duty. Monthly compliance rates were assessed by a multidisciplinary team for development of strategies for real-time improvement. Compliance and outcomes were captured over 1 year of QRC use.

Results: QRC use was associated with a sustained improvement of VAP bundle and other compliance measures over a year of use. After multivariable analysis adjusting for age (> 55), injury mechanism, Glasgow Coma Scale score (≤ 8), and Injury Severity Score (> 20), the rate of VAP was significantly lower after QRC use, with an adjusted mean difference of -6.65 (per 1,000 device days; 95% confidence interval, -9.27 to -4.04; p = 0.008). During the year of QRC use, 3% of patients developed a VAP if all four daily bundle measures were met for the duration of ICU stay versus 14% in those with partial compliance (p = 0.04). The overall VAP rate with full compliance was 5.29 versus 9.23 (per 1,000 device days) with partial compliance. Compared with the previous year, a 24% decrease in the number of pneumonias was recorded for the year of QRC use, representing an estimated cost savings of approximately $400,000.

Conclusion: The use of a QRC facilitates sustainable improvement in compliance rates for clinically significant prophylactic measures in a busy Level I trauma ICU. The daily use of the QRC, requiring just a few minutes per patient to complete, equates to cost-effective improvement in patient outcomes.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms