Effects of pulsed, spatially fractionated, microscopic synchrotron X-ray beams on normal and tumoral brain tissue
- PMID: 20034592
- DOI: 10.1016/j.mrrev.2009.12.003
Effects of pulsed, spatially fractionated, microscopic synchrotron X-ray beams on normal and tumoral brain tissue
Abstract
Microbeam radiation therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600keV, produced by third generation synchrotron sources, such as the European Synchrotron Radiation Facility (ESRF), in France. The main advantages of highly brilliant synchrotron sources are an extremely high dose rate and very small beam divergence. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. The minimal beam divergence results in the advantage of steeper dose gradients delivered to a tumor target, thus achieving a higher dose deposition in the target volume in fractions of seconds, with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has yielded many results from preclinical trials based on different animal models, including mice, rats, piglets and rabbits. Typically, MRT uses arrays of narrow ( approximately 25-100 microm wide) microplanar beams separated by wider (100-400 microm centre-to-centre) microplanar spaces. The height of these microbeams typically varies from 1 to 100 mm, depending on the target and the desired preselected field size to be irradiated. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues, up to approximately 2 yr after irradiation, and at the same time show a preferential damage of malignant tumor tissues; these effects of MRT have now been extensively studied over nearly two decades. More recently, some biological in vivo effects of synchrotron X-ray beams in the millimeter range (0.68-0.95 mm, centre-to-centre distances 1.2-4 mm), which may differ to some extent from those of microscopic beams, have been followed up to approximately 7 months after irradiation. Comparisons between broad-beam irradiation and MRT indicate a higher tumor control for the same sparing of normal tissue in the latter, even if a substantial fraction of tumor cells are not receiving a radiotoxic level of radiation. The hypothesis of a selective radiovulnerability of the tumor vasculature versus normal blood vessels by MRT, and of the cellular and molecular mechanisms involved remains under investigation. The paper highlights the history of MRT including salient biological findings after microbeam irradiation with emphasis on the vascular components and the tolerance of the central nervous system. Details on experimental and theoretical dosimetry of microbeams, core issues and possible therapeutic applications of MRT are presented.
2010 Elsevier B.V. All rights reserved.
Similar articles
-
Response of avian embryonic brain to spatially segmented x-ray microbeams.Cell Mol Biol (Noisy-le-grand). 2001 May;47(3):485-93. Cell Mol Biol (Noisy-le-grand). 2001. PMID: 11441956
-
Medical physics aspects of the synchrotron radiation therapies: Microbeam radiation therapy (MRT) and synchrotron stereotactic radiotherapy (SSRT).Phys Med. 2015 Sep;31(6):568-83. doi: 10.1016/j.ejmp.2015.04.016. Epub 2015 Jun 1. Phys Med. 2015. PMID: 26043881 Review.
-
Synchrotron microbeam radiation therapy for rat brain tumor palliation-influence of the microbeam width at constant valley dose.Phys Med Biol. 2009 Nov 7;54(21):6711-24. doi: 10.1088/0031-9155/54/21/017. Epub 2009 Oct 20. Phys Med Biol. 2009. PMID: 19841517
-
Microbeam radiation therapy: tissue dose penetration and BANG-gel dosimetry of thick-beams' array interlacing.Eur J Radiol. 2008 Dec;68(3 Suppl):S129-36. doi: 10.1016/j.ejrad.2008.04.055. Epub 2008 Jul 7. Eur J Radiol. 2008. PMID: 18606516
-
Effects of microbeam radiation therapy on normal and tumoral blood vessels.Phys Med. 2015 Sep;31(6):634-41. doi: 10.1016/j.ejmp.2015.04.014. Epub 2015 May 23. Phys Med. 2015. PMID: 26004351 Review.
Cited by
-
Generation of low-flux X-ray micro-planar beams and their biological effect on a murine subcutaneous tumor model.J Radiat Res. 2015 Sep;56(5):768-76. doi: 10.1093/jrr/rrv037. Epub 2015 Jul 3. J Radiat Res. 2015. PMID: 26141370 Free PMC article.
-
Microbeam radiation therapy - grid therapy and beyond: a clinical perspective.Br J Radiol. 2017 Oct;90(1078):20170073. doi: 10.1259/bjr.20170073. Epub 2017 Jul 27. Br J Radiol. 2017. PMID: 28749174 Free PMC article. Review.
-
A high-resolution dose calculation engine for X-ray microbeams radiation therapy.Med Phys. 2022 Jun;49(6):3999-4017. doi: 10.1002/mp.15637. Epub 2022 Apr 12. Med Phys. 2022. PMID: 35342953 Free PMC article.
-
Synchrotron X ray induced axonal transections in the brain of rats assessed by high-field diffusion tensor imaging tractography.PLoS One. 2014 Feb 5;9(2):e88244. doi: 10.1371/journal.pone.0088244. eCollection 2014. PLoS One. 2014. PMID: 24505446 Free PMC article.
-
Pencilbeam irradiation technique for whole brain radiotherapy: technical and biological challenges in a small animal model.PLoS One. 2013;8(1):e54960. doi: 10.1371/journal.pone.0054960. Epub 2013 Jan 28. PLoS One. 2013. PMID: 23383014 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous