Circumferential pulmonary vein isolation and linear left atrial ablation as a single-catheter technique to achieve bidirectional conduction block: the pace-and-ablate approach
- PMID: 20036199
- DOI: 10.1016/j.hrthm.2009.10.003
Circumferential pulmonary vein isolation and linear left atrial ablation as a single-catheter technique to achieve bidirectional conduction block: the pace-and-ablate approach
Abstract
Background: Pulmonary vein (PV) isolation has become a cornerstone for ablation of atrial fibrillation (AF). Circular mapping catheter (CMC)-guided techniques for detection of lesion gaps are challenging.
Objective: The present study describes a new concept of circumferential PV ablation aiming at bidirectional conduction block based on simultaneous pacing and ablation through the tip of a single mapping/ablation catheter.
Methods: A total of 147 patients with AF received circumferential PV ablation. In persistent AF, a posterior "box" lesion and a mitral isthmus line were added. All procedures were performed in sinus rhythm. Gaps within the left atrial (LA) ablation lines were detected and closed using voltage and pace mapping through the mapping/ablation catheter. Bidirectional conduction block was the procedural end point. Subsequently, the end point was validated by an independent electrophysiologist using a CMC.
Results: Procedural and radiation time measured 188 +/- 55 and 37 +/- 15 min. Bidirectional PV conduction block (lack of PV potentials and lack of LA capture) was found in 140 of 147 (95%) patients with single mapping/ablation catheter and in 138 of 147 (94%) patients with CMC. Early PV reconduction was seen in 22 of 147 (15%) patients. After 12 months follow-up, 84% of the patients were free from AF and/or atrial macro-re-entrant tachycardia. The rate of reablations was 10% and 24% for patients with paroxysmal and persistent AF, respectively.
Conclusion: Pacing and ablation from the tip of the mapping/ablation catheter is feasible to detect and close gaps within long atrial ablation lines to consistently achieve bidirectional conduction block.
Comment in
-
How should we evaluate a new technique in a constantly changing world? The Pace and Ablate study.Heart Rhythm. 2010;7(2):165-6. doi: 10.1016/j.hrthm.2009.10.031. Epub 2009 Oct 28. Heart Rhythm. 2010. PMID: 20036198 No abstract available.
Similar articles
-
Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation.Heart Rhythm. 2010 Mar;7(3):323-30. doi: 10.1016/j.hrthm.2009.11.011. Epub 2009 Nov 12. Heart Rhythm. 2010. PMID: 20185104
-
Recovery of mitral isthmus conduction leads to the development of macro-reentrant tachycardia after left atrial linear ablation for atrial fibrillation.Circ Arrhythm Electrophysiol. 2011 Dec;4(6):832-7. doi: 10.1161/CIRCEP.111.964817. Epub 2011 Sep 30. Circ Arrhythm Electrophysiol. 2011. PMID: 21965530
-
[Interventional therapy of atrial fibrillation: possibilities and limitations].Dtsch Med Wochenschr. 2010 Mar;135 Suppl 2:S48-54. doi: 10.1055/s-0030-1249209. Epub 2010 Mar 10. Dtsch Med Wochenschr. 2010. PMID: 20221979 Review. German.
-
Effect of mitral isthmus block on development of atrial tachycardia following ablation for atrial fibrillation.Pacing Clin Electrophysiol. 2010 Apr;33(4):460-8. doi: 10.1111/j.1540-8159.2009.02625.x. Epub 2009 Dec 1. Pacing Clin Electrophysiol. 2010. PMID: 19954501
-
Catheter Ablation for Long-Standing Persistent Atrial Fibrillation.Methodist Debakey Cardiovasc J. 2015 Apr-Jun;11(2):87-93. doi: 10.14797/mdcj-11-2-87. Methodist Debakey Cardiovasc J. 2015. PMID: 26306125 Free PMC article. Review.
Cited by
-
Effect of remote ischemic preconditioning on electrophysiological and biomolecular parameters in nonvalvular paroxysmal atrial fibrillation (RIPPAF study): Rationale and study design of a randomized, controlled clinical trial.Clin Cardiol. 2016 Nov;39(11):631-635. doi: 10.1002/clc.22584. Epub 2016 Oct 24. Clin Cardiol. 2016. PMID: 27775830 Free PMC article. Clinical Trial.
-
Gastric ablation as a novel technique for modulating electrical conduction in the in vivo stomach.Am J Physiol Gastrointest Liver Physiol. 2021 Apr 1;320(4):G573-G585. doi: 10.1152/ajpgi.00448.2020. Epub 2021 Jan 20. Am J Physiol Gastrointest Liver Physiol. 2021. PMID: 33470186 Free PMC article.
-
Comparison of left atrial dimensions in CT and echocardiography as predictors of long-term success after catheter ablation of atrial fibrillation.J Interv Card Electrophysiol. 2015 Sep;43(3):237-44. doi: 10.1007/s10840-015-0010-8. Epub 2015 May 9. J Interv Card Electrophysiol. 2015. PMID: 25956477 Clinical Trial.
-
Radiofrequency ablation of atrial fibrillation using a single catheter approach: time to lose the halo.J Interv Card Electrophysiol. 2023 Mar;66(2):249-252. doi: 10.1007/s10840-022-01353-3. Epub 2022 Sep 7. J Interv Card Electrophysiol. 2023. PMID: 36070030 No abstract available.
-
Safety and Feasibility of Contrast Injection During Pulmonary Vein Isolation with the nMARQ™ Multi-Electrode Catheter.J Atr Fibrillation. 2015 Dec 31;8(4):1324. doi: 10.4022/jafib.1324. eCollection 2015 Dec. J Atr Fibrillation. 2015. PMID: 27957231 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical