Quantitative descriptors of corneal topography. A clinical study
- PMID: 2003793
- DOI: 10.1001/archopht.1991.01080030051037
Quantitative descriptors of corneal topography. A clinical study
Abstract
Quantitative descriptors of corneal topography determined by computerized algorithm and designed to augment the information derived from topographic maps were evaluated in a clinical study. The surface regularity index, a measure of central corneal optical quality, was highly correlated with best spectacle-corrected visual acuity (rho = 0.80, P less than .001). The relatively low correlation between the surface asymmetry index, a measure of central corneal asymmetry, and best spectacle-corrected visual acuity (rho = 0.62, P less than .005) suggests that corneal symmetry is a lesser but still important determinant of the optical performance of the anterior corneal surface. There was also a high correlation between factors determined from computer-generated orthogonal simulated keratometer values and clinical keratometry values (mean corneal power, total corneal cylinder, and the location of the steepest corneal meridian). The information derived from these algorithms has both clinical and research applications and can be incorporated into computer-assisted topographic analysis systems.
Similar articles
-
Quantitative descriptors of corneal shape derived from computer-assisted analysis of photokeratographs.Refract Corneal Surg. 1989 Nov-Dec;5(6):372-8. Refract Corneal Surg. 1989. PMID: 2488834
-
Quantitative topographic irregularity as a predictor of spectacle-corrected visual acuity after refractive surgery.Am J Ophthalmol. 2000 Jun;129(6):752-8. doi: 10.1016/s0002-9394(00)00471-2. Am J Ophthalmol. 2000. PMID: 10926984
-
Advances in the analysis of corneal topography.Surv Ophthalmol. 1991 Jan-Feb;35(4):269-77. doi: 10.1016/0039-6257(91)90047-j. Surv Ophthalmol. 1991. PMID: 2011820 Review.
-
Corneal topographic changes after refitting polymethylmethacrylate contact lens wearers into rigid gas permeable materials.CLAO J. 1995 Jan;21(1):47-51. CLAO J. 1995. PMID: 7712607
-
[Quantitative assessment of quality of vision].Nippon Ganka Gakkai Zasshi. 2004 Dec;108(12):770-807; discussion 808. Nippon Ganka Gakkai Zasshi. 2004. PMID: 15656087 Review. Japanese.
Cited by
-
Application of Corvis ST to evaluate the effect of femtosecond laser-assisted cataract surgery on corneal biomechanics.Exp Ther Med. 2017 Aug;14(2):1626-1632. doi: 10.3892/etm.2017.4675. Epub 2017 Jun 26. Exp Ther Med. 2017. PMID: 28781631 Free PMC article.
-
Proposed classification for topographic patterns seen after penetrating keratoplasty.Br J Ophthalmol. 1999 Apr;83(4):403-9. doi: 10.1136/bjo.83.4.403. Br J Ophthalmol. 1999. PMID: 10434860 Free PMC article.
-
A randomised, prospective study comparing trabeculectomy augmented with antimetabolites with a viscocanalostomy technique for the management of open angle glaucoma uncontrolled by medical therapy.Br J Ophthalmol. 2002 Jul;86(7):748-54. doi: 10.1136/bjo.86.7.748. Br J Ophthalmol. 2002. PMID: 12084743 Free PMC article. Clinical Trial.
-
Quantitative evaluation of night vision and correlation of refractive and topographical parameters with glare after orthokeratology.Graefes Arch Clin Exp Ophthalmol. 2011 Oct;249(10):1519-26. doi: 10.1007/s00417-011-1696-7. Epub 2011 May 12. Graefes Arch Clin Exp Ophthalmol. 2011. PMID: 21562891
-
Excimer laser in-situ keratomileusis (LASIK) under a corneal flap for myopia of 2 to 20 D.Trans Am Ophthalmol Soc. 1995;93:163-83; discussion 184-90. Trans Am Ophthalmol Soc. 1995. PMID: 8719677 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical