Conversion degree of indirect resin composites and effect of thermocycling on their physical properties
- PMID: 20040031
- DOI: 10.1111/j.1532-849X.2009.00551.x
Conversion degree of indirect resin composites and effect of thermocycling on their physical properties
Abstract
Purpose: This study evaluated the degree of conversion (DC) of four indirect resin composites (IRCs) with various compositions processed in different polymerization units and investigated the effect of thermal aging on the flexural strength and Vicker's microhardness.
Materials and methods: Specimens were prepared from four IRC materials, namely Gr 1: Resilab (Wilcos); Gr2: Sinfony (3M ESPE); Gr3: VITA VMLC (VITA Zahnfabrik); Gr4: VITA Zeta (VITA Zahnfabrik) using special molds for flexural strength test (N = 80, n = 10 per group) (25 x 2 x 2 mm(3), ISO 4049), for Vicker's microhardness test (N = 80, n = 10 per group) (5 x 4 mm(2)) and for DC (N = 10) using FT-Raman Spectroscopy. For both flexural strength and microhardness tests, half of the specimens were randomly stored in distilled water at 37 degrees C for 24 hours (Groups 1 to 4), and the other half (Groups 5 to 8) were subjected to thermocycling (5000 cycles, 5 to 55 +/- 1 degree C, dwell time: 30 seconds). Flexural strength was measured in a universal testing machine (crosshead speed: 0.8 mm/min). Microhardness test was performed at 50 g. The data were analyzed using one-way and two-way ANOVA and Tukey's test (alpha= 0.05). The correlation between flexural strength and microhardness was evaluated with Pearson's correlation test (alpha= 0.05).
Results: A significant effect for the type of IRC and thermocycling was found (p= 0.001, p= 0.001) on the flexural strength results, but thermocycling did not significantly affect the microhardness results (p= 0.078). The interaction factors were significant for both flexural strength and microhardness parameters (p= 0.001 and 0.002, respectively). Thermocycling decreased the flexural strength of the three IRCs tested significantly (p < 0.05), except for VITA Zeta (106.3 +/- 9.1 to 97.2 +/- 14 MPa) (p > 0.05) when compared with nonthermocycled groups. Microhardness results of only Sinfony were significantly affected by thermocycling (25.1 +/- 2.1 to 31 +/- 3.3 Kg/mm(2)). DC values ranged between 63% and 81%, and were not significantly different between the IRCs (p > 0.05). While a positive correlation was found between flexural strength and microhardness without (r = 0.309) and with thermocycling (r = 0.100) for VITA VMLC, negative correlations were found for Resilab under the same conditions (r =-0.190 and -0.305, respectively) (Pearson's correlation coefficient).
Conclusion: Although all four IRCs presented nonsignificant DC values, flexural strength and microhardness values varied between materials with and without thermocycling.
Similar articles
-
Effect of propionaldehyde or 2,3-butanedione additives on the mechanical properties of Bis-GMA analog-based composites.Dent Mater. 2009 Jan;25(1):26-32. doi: 10.1016/j.dental.2008.05.002. Epub 2008 Aug 30. Dent Mater. 2009. PMID: 18757084
-
Effect of repeated preheating cycles on flexural strength of resin composites.Oper Dent. 2013 Jan-Feb;38(1):33-8. doi: 10.2341/11-476-L. Epub 2012 Jul 7. Oper Dent. 2013. PMID: 22770484
-
Effect of water storage, thermocycling, the incorporation and site of placement of glass-fibers on the flexural strength of veneering composite.Dent Mater. 2005 Aug;21(8):761-72. doi: 10.1016/j.dental.2005.01.013. Dent Mater. 2005. PMID: 15885765
-
Elution of leachable components from composites.J Oral Rehabil. 1994 Jul;21(4):441-52. doi: 10.1111/j.1365-2842.1994.tb01158.x. J Oral Rehabil. 1994. PMID: 7965355 Review.
-
Preheating of dental composite resins: A scoping review.J Esthet Restor Dent. 2023 Jun;35(4):646-656. doi: 10.1111/jerd.12991. Epub 2022 Dec 7. J Esthet Restor Dent. 2023. PMID: 36478368
Cited by
-
The impact of temperature on the shear bond strength of conventional multi-step and self-adhesive orthodontic adhesive systems: an in-vitro study.BMC Oral Health. 2025 Feb 5;25(1):189. doi: 10.1186/s12903-025-05515-3. BMC Oral Health. 2025. PMID: 39910542 Free PMC article.
-
The Effect of Thermocycling on Surface Layer Properties of Light Cured Polymer Matrix Ceramic Composites (PMCCs) Used in Sliding Friction Pair.Materials (Basel). 2019 Aug 29;12(17):2776. doi: 10.3390/ma12172776. Materials (Basel). 2019. PMID: 31470526 Free PMC article.
-
Evaluation of the Degree of Conversion, Residual Monomers and Mechanical Properties of Some Light-Cured Dental Resin Composites.Materials (Basel). 2019 Jun 30;12(13):2109. doi: 10.3390/ma12132109. Materials (Basel). 2019. PMID: 31262014 Free PMC article.
-
Effect of thermocycling on the mechanical properties of permanent composite-based CAD-CAM restorative materials produced by additive and subtractive manufacturing techniques.BMC Oral Health. 2024 Mar 14;24(1):334. doi: 10.1186/s12903-024-04016-z. BMC Oral Health. 2024. PMID: 38486195 Free PMC article.
-
The effect of prophylactic polishing pastes on surface roughness of indirect restorative materials.ScientificWorldJournal. 2014 Mar 3;2014:962764. doi: 10.1155/2014/962764. eCollection 2014. ScientificWorldJournal. 2014. PMID: 24729757 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical