Clinical feasibility of a magnetic resonance tracking system to guide the position of the scan plane during physiologic joint motion
- PMID: 20041313
- DOI: 10.1007/s11547-009-0485-4
Clinical feasibility of a magnetic resonance tracking system to guide the position of the scan plane during physiologic joint motion
Abstract
Purpose: Unrestricted physiologic joint motion results in multidirectional displacement of the anatomic structures. When performing real-time magnetic resonance (MR) imaging of such a joint motion, continuous adjustment of the scan plane position may be required. The purpose of this study was to evaluate the clinical feasibility of a method to guide the scan plane position during dynamic-motion MR imaging of freely moving joints.
Materials and methods: The location of a small tracker device (dedicated hardware) placed on the patient's skin overlying a joint was determined by an ultrashort MR sequence and used to automatically adjust the scan plane position prior to each dynamic-motion MR image. Using a vertically open MR unit, this MR tracking system was applied in ten dynamic-motion MR examinations to evaluate flexion/extension manoeuvres in the weight-bearing knee joint, and in ten dynamic-motion MR examinations of the shoulder joint to evaluate manoeuvres such as internal/external rotation of the humerus, stress testing of the glenohumeral joint and abduction/adduction manoeuvres. Average number of manoeuvre repetitions, total number of images and percentage of useful images per manoeuvre were calculated. Imaging time per scan plane for each manoeuvre was recorded.
Results: Average repetition of manoeuvres varied between 1.6 and 5.8, with an average number of 7 to 18 images per manoeuvre. Average percentage of useful images varied between 61% and 89%. Total imaging time per scan plane ranged between 1 min 10 s and 4 min 51 s.
Conclusions: The MR tracking system to guide the slice position for each consecutive dynamic-motion MR image of the freely but slowly moving shoulder or knee joint was feasible for clinical use, providing a high percentage of useful images for each manoeuvre within a clinically acceptable time frame.
Similar articles
-
Glenohumeral relationships during physiologic shoulder motion and stress testing: initial experience with open MR imaging and active imaging-plane registration.Radiology. 1999 Sep;212(3):699-705. doi: 10.1148/radiology.212.3.r99se31699. Radiology. 1999. PMID: 10478235
-
Joint motion in an open MR unit using MR tracking.J Magn Reson Imaging. 1999 Jul;10(1):8-14. doi: 10.1002/(sici)1522-2586(199907)10:1<8::aid-jmri2>3.0.co;2-2. J Magn Reson Imaging. 1999. PMID: 10398972
-
Dynamic MR imaging and stress testing in glenohumeral instability: comparison with normal shoulders and clinical/surgical findings.J Magn Reson Imaging. 2001 May;13(5):748-56. doi: 10.1002/jmri.1104. J Magn Reson Imaging. 2001. PMID: 11329197
-
All-in-one magnetic resonance arthrography of the shoulder in a vertically open magnetic resonance unit.Acta Radiol. 2008 Oct;49(8):918-27. doi: 10.1080/02841850802291242. Acta Radiol. 2008. PMID: 18651257 Clinical Trial.
-
In vivo kinematic analysis of the glenohumeral joint during dynamic full axial rotation and scapular plane full abduction in healthy shoulders.Knee Surg Sports Traumatol Arthrosc. 2017 Jul;25(7):2032-2040. doi: 10.1007/s00167-016-4263-2. Epub 2016 Aug 10. Knee Surg Sports Traumatol Arthrosc. 2017. PMID: 27511218
References
MeSH terms
LinkOut - more resources
Full Text Sources
Medical