T2-weighted MRI of the upper abdomen: comparison of four fat-suppressed T2-weighted sequences including PROPELLER (BLADE) technique
- PMID: 20042352
- DOI: 10.1016/j.acra.2009.10.015
T2-weighted MRI of the upper abdomen: comparison of four fat-suppressed T2-weighted sequences including PROPELLER (BLADE) technique
Abstract
Rationale and objectives: The aim of this study was to compare four different fat-suppressed T2-weighted sequences with different techniques with regard to image quality and lesion detection in upper abdominal magnetic resonance imaging (MRI) scans.
Materials and methods: Thirty-two consecutive patients referred for upper abdominal MRI for the evaluation of various suspected pathologies were included in this study. Different T2-weighted sequences (free-breathing navigator-triggered turbo spin-echo [TSE], free-breathing navigator-triggered TSE with restore pulse (RP), breath-hold TSE with RP, and free-breathing navigator-triggered TSE with RP using the periodically rotated overlapping parallel lines with enhanced reconstruction technique [using BLADE, a Siemens implementation of this technique]) were used on all patients. All images were assessed independently by two radiologists. Assessments of motion artifacts; the edge sharpness of the liver, pancreas, and intrahepatic vessels; depictions of the intrahepatic vessels; and overall image quality were performed qualitatively. Quantitative analysis was performed by calculation of the signal-to-noise ratios for liver tissue and gallbladder as well as contrast-to-noise ratios of liver to spleen.
Results: Liver and gallbladder signal-to-noise ratios as well as liver to spleen contrast-to-noise ratios were significantly higher (P < .05) for the BLADE technique compared to all other sequences. In qualitative analysis, the severity of motion artifacts was significantly lower with T2-weighted free-breathing navigator-triggered BLADE sequences compared to other sequences (P < .01). The edge sharpness of the liver, pancreas, and intrahepatic vessels; depictions of the intrahepatic vessels; and overall image quality were significantly better with the BLADE sequence (P < .05).
Conclusion: The T2-weighted free-breathing navigator-triggered TSE sequence with the BLADE technique is a promising approach for reducing motion artifacts and improving image quality in upper abdominal MRI scans.
Similar articles
-
Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction.J Magn Reson Imaging. 2005 May;21(5):576-82. doi: 10.1002/jmri.20293. J Magn Reson Imaging. 2005. PMID: 15834908
-
Image quality and focal lesion detection on T2-weighted MR imaging of the liver: comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques.J Magn Reson Imaging. 2007 Aug;26(2):323-30. doi: 10.1002/jmri.21002. J Magn Reson Imaging. 2007. PMID: 17610287
-
Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen.J Magn Reson Imaging. 2008 Oct;28(4):957-62. doi: 10.1002/jmri.21538. J Magn Reson Imaging. 2008. PMID: 18821630
-
BLADE Sequences in Transverse T2-weighted MR Imaging of the Cervical Spine. Cut-off for Artefacts?Rofo. 2015 May;36(2):102-8. doi: 10.1055/s-0034-1385179. Epub 2014 Sep 22. Rofo. 2015. PMID: 25912327 Review.
-
Advances in abdominal MR imaging.Radiographics. 1998 Nov-Dec;18(6):1569-86. doi: 10.1148/radiographics.18.6.9821200. Radiographics. 1998. PMID: 9821200 Review.
Cited by
-
Performance of PROPELLER FSE T2WI in reducing metal artifacts of material porcelain fused to metal crown: a clinical preliminary study.Sci Rep. 2022 May 19;12(1):8442. doi: 10.1038/s41598-022-12402-2. Sci Rep. 2022. PMID: 35589945 Free PMC article.
-
[Modern magnetic resonance imaging of the liver].Radiologe. 2015 Dec;55(12):1045-56. doi: 10.1007/s00117-015-0031-4. Radiologe. 2015. PMID: 26628259 Review. German.
-
Periodically rotated overlapping parallel lines with enhanced reconstruction acquisition to improve motion-induced artifacts in bladder cancer imaging: Initial findings.Medicine (Baltimore). 2019 Oct;98(42):e17075. doi: 10.1097/MD.0000000000017075. Medicine (Baltimore). 2019. PMID: 31626080 Free PMC article.
-
Free-Breathing Liver Magnetic Resonance Imaging With Respiratory Frequency-Modulated Continuous-Wave Radar-Trigger Technique: A Preliminary Study.Front Oncol. 2022 Jun 1;12:918173. doi: 10.3389/fonc.2022.918173. eCollection 2022. Front Oncol. 2022. PMID: 35719930 Free PMC article.
-
Accelerated Abdominal MRI: A Review of Current Methods and Applications.J Magn Reson Imaging. 2025 Sep;62(3):654-672. doi: 10.1002/jmri.29750. Epub 2025 Mar 18. J Magn Reson Imaging. 2025. PMID: 40103292 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical