Background: Unlike Resuscitation Guidelines (GL) 2000, GL2005 advise resuming cardiopulmonary resuscitation (CPR) immediately after defibrillation. We hypothesized that immediate CPR resumption promotes earlier recurrence of ventricular fibrillation (VF).
Methods and results: This study used data of a prospective per-patient randomized controlled trial. Automated external defibrillators used by first responders were randomized to either (1) perform postshock analysis and prompt rescuers to a pulse check (GL2000), or (2) resume CPR immediately after defibrillation (GL2005). Continuous recordings of ECG and impedance signals were collected from all patients with an out-of-hospital cardiac arrest to whom a randomized automated external defibrillator was applied. We included patients with VF as their initial rhythm in whom CPR onset could be determined from the ECG and impedance signals. Time intervals are presented as median (Q1-to-Q3). Of 361 patients, 136 met the inclusion criteria: 68 were randomly assigned to GL2000 and 68 to GL2005. Rescuers resumed CPR 30 (21-to-39) and 8 (7-to-9) seconds, respectively, after the first shock that successfully terminated VF (P<0.001); VF recurred after 40 (21-to-76) and 21 (10-to-80) seconds, respectively (P=0.001). The time interval between start of CPR and VF recurrence was 6 (0-to-67) and 8 (3-to-61) seconds, respectively (P=0.88). The hazard ratio for VF recurrence in the first 2 seconds of CPR was 15.5 (95% confidence interval, 5.63 to 57.7) compared with before CPR resumption. After more than 8 seconds of CPR, the hazard of VF recurrence was similar to before CPR resumption.
Conclusions: Early CPR resumption after defibrillation causes early VF recurrence. Clinical Trial Registration- clinicaltrials.gov Identifier: ISRCTN72257677.
Similar articles
-
Resumption of chest compressions after successful defibrillation and risk for recurrence of ventricular fibrillation in out-of-hospital cardiac arrest.Circ Arrhythm Electrophysiol. 2014 Aug;7(4):633-9. doi: 10.1161/CIRCEP.114.001506. Epub 2014 Jul 11. Circ Arrhythm Electrophysiol. 2014. PMID: 25015946
-
Automated external defibrillators: to what extent does the algorithm delay CPR?Ann Emerg Med. 2005 Aug;46(2):132-41. doi: 10.1016/j.annemergmed.2005.04.001. Ann Emerg Med. 2005. PMID: 16046942
-
Out-of-hospital defibrillation with automated external defibrillators: postshock analysis should be delayed.Ann Emerg Med. 2001 Sep;38(3):256-61. doi: 10.1067/mem.2001.116596. Ann Emerg Med. 2001. PMID: 11524644
-
[Analysis of ventricular fibrillation signals for the evaluation of defibrillation success in the treatment of ventricular fibrillation].Anasthesiol Intensivmed Notfallmed Schmerzther. 2003 Dec;38(12):787-94. doi: 10.1055/s-2003-45401. Anasthesiol Intensivmed Notfallmed Schmerzther. 2003. PMID: 14666442 Review. German.
-
The best timing for defibrillation in shockable cardiac arrest.Minerva Anestesiol. 2013 Jan;79(1):92-101. Epub 2012 Oct 22. Minerva Anestesiol. 2013. PMID: 23090104 Review.
Cited by
-
Identification of return of spontaneous circulation during cardiopulmonary resuscitation via pulse oximetry in a porcine animal cardiac arrest model.J Clin Monit Comput. 2019 Oct;33(5):843-851. doi: 10.1007/s10877-018-0230-4. Epub 2018 Nov 29. J Clin Monit Comput. 2019. PMID: 30498975
-
Rabbit models of cardiac mechano-electric and mechano-mechanical coupling.Prog Biophys Mol Biol. 2016 Jul;121(2):110-22. doi: 10.1016/j.pbiomolbio.2016.05.003. Epub 2016 May 18. Prog Biophys Mol Biol. 2016. PMID: 27208698 Free PMC article. Review.
-
Influence of Chest Compressions on Circulation during the Peri-Cardiac Arrest Period in Porcine Models.PLoS One. 2016 May 11;11(5):e0155212. doi: 10.1371/journal.pone.0155212. eCollection 2016. PLoS One. 2016. PMID: 27168071 Free PMC article.
-
Cardiopulmonary resuscitation: when guidelines provide no answers.Anaesthesist. 2019 Apr;68(4):239-244. doi: 10.1007/s00101-019-0561-7. Epub 2019 Apr 1. Anaesthesist. 2019. PMID: 30937467 English.
-
The importance of non-uniformities in mechano-electric coupling for ventricular arrhythmias.J Interv Card Electrophysiol. 2014 Jan;39(1):25-35. doi: 10.1007/s10840-013-9852-0. Epub 2013 Dec 12. J Interv Card Electrophysiol. 2014. PMID: 24338157 Review.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous