Theory and application of diffuse infrared biotelemetry
- PMID: 2004534
Theory and application of diffuse infrared biotelemetry
Abstract
For biomedical applications the most significant is diffuse indoor infrared telemetry. The advantages and disadvantages of infrared diffuse biotelemetry in comparison to RF biotelemetry are presented. Design of the transmitter-receiver link is described and it is shown how efficiency coefficient of the link can be optimized. The whole room can be covered with infrared radiation because of room wall reflections. The distribution and reflections of infrared radiation are analyzed to calculate their most significant parameters and compare them with measured data. One very efficient infrared telemetry system is described and its characteristics are given. To realize a multichannel system inside one room, an asynchronous and a synchronous mode are feasible. The asynchronous mode is characterized with simplicity but the number of channels is very limited. However, the synchronous mode is more sophisticated and complex but acts as a multichannel system without any interference between channels. The realization of both systems is described. In the case that the infrared radiation in some part of the room is not sufficient, an infrared relay can be applied. At the end, a survey of the infrared telemetry application in medicine is given.
Similar articles
-
Theory and applications of biotelemetry.J Med Syst. 2002 Apr;26(2):159-78. doi: 10.1023/a:1014862027454. J Med Syst. 2002. PMID: 11993572 Review.
-
[A multichannel infrared telemetry system for physiological signal].Zhongguo Yi Liao Qi Xie Za Zhi. 1999 Jan;23(1):16-8. Zhongguo Yi Liao Qi Xie Za Zhi. 1999. PMID: 12583031 Chinese.
-
Modern patient care using biotelemetry: its potential and technical realization at present and in the future.Med Prog Technol. 1982;9(2-3):85-93. Med Prog Technol. 1982. PMID: 7162496
-
Biotelemetry, based on optical transmission.Biotelem Patient Monit. 1982;9(3):129-43. Biotelem Patient Monit. 1982. PMID: 7159699
-
Biomedical telemetry techniques.Crit Rev Biomed Eng. 1982 Feb;7(2):121-74. Crit Rev Biomed Eng. 1982. PMID: 7047072 Review.
Cited by
-
Infrared transmission of electronic information via LAN in the operating room.J Clin Monit Comput. 2000;16(3):171-5. doi: 10.1023/a:1009911208828. J Clin Monit Comput. 2000. PMID: 12578100
-
Theory and applications of biotelemetry.J Med Syst. 2002 Apr;26(2):159-78. doi: 10.1023/a:1014862027454. J Med Syst. 2002. PMID: 11993572 Review.