Evaluation of the sensitivity of an in vitro high frequency ultrasound device to monitor the coagulation process: study of the effects of heparin treatment in a murine model
- PMID: 20045589
- DOI: 10.1016/j.ultrasmedbio.2009.10.010
Evaluation of the sensitivity of an in vitro high frequency ultrasound device to monitor the coagulation process: study of the effects of heparin treatment in a murine model
Abstract
This study evaluates the sensitivity of a new in vitro high frequency ultrasound test of the whole blood coagulation process. A rat model of anticoagulant treatment is reported. Many recent studies of the role of red blood cells in the whole blood coagulation process have revealed an increasing demand for global tests of the coagulation process performed on whole blood instead of plasma samples. In contrast to existing optical tests, high frequency ultrasound presents the advantages of characterizing the mechanical properties of whole blood clotting. Ultrasound longitudinal wave velocity and integrated attenuation coefficient (IAC) were simultaneously assessed in a 10 to 30 MHz frequency range during the whole blood coagulation process in vitro in rats under anticoagulant therapy. Differences between humans and rats were also clearly emphasized in non-clotting blood and in clotting blood using specific criteria deduced from acoustic parameters (ultrasound velocity for non-clotting blood:=1574+/-2m/s for rats and 1583+/-3m/s for humans and IAC=2.25+/-0.14 dB/cm for rats and 1.5+/-0.23 dB/cm for humans). We also measured the coagulation time t(0) from the acoustic velocity (t(0) =11.15+/-7 min for control rat blood and 43.3+/-11.4 min for human blood). Different doses of heparin were administered to rats. The sensitivity of the ultrasound device to the effects of heparin was evaluated. Differences between non-treated rats and chronically and acutely treated rats were recorded and quantified. We particularly noted that the slope S and the amplitude I of the variations in acoustic velocity were linked to clot retraction, which is a good indicator of the platelet function. The amplitude of the variations in S was between (20+/-8) x1 0(-3) m/s(2) for control group rats, and (0.92+/-0.35) x 10(-3) m/s(2) for chronic heparin-treated group rats. The values of I were 15 times higher for control group rats than for chronic heparin-treated group rats.
2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Similar articles
-
High frequency ultrasound device to investigate the acoustic properties of whole blood during coagulation.Ultrasound Med Biol. 2008 Feb;34(2):252-64. doi: 10.1016/j.ultrasmedbio.2007.06.018. Ultrasound Med Biol. 2008. PMID: 18077082
-
Interest of the attenuation coefficient in multiparametric high frequency ultrasound investigation of whole blood coagulation process.J Acoust Soc Am. 2009 Jan;125(1):530-8. doi: 10.1121/1.3021439. J Acoust Soc Am. 2009. PMID: 19173438
-
In vivo and in vitro evaluation of the heparin management test versus the activated coagulation time for monitoring anticoagulation level in aprotinin-treated patients during cardiac surgery.Heart Surg Forum. 2004;7(6):E599-604. doi: 10.1532/HSF98.20041134. Heart Surg Forum. 2004. PMID: 15769695 Clinical Trial.
-
Development of platelet contractile force as a research and clinical measure of platelet function.Cell Biochem Biophys. 2003;38(1):55-78. doi: 10.1385/CBB:38:1:55. Cell Biochem Biophys. 2003. PMID: 12663942 Review.
-
Safety and nutritional assessment of GM plants and derived food and feed: the role of animal feeding trials.Food Chem Toxicol. 2008 Mar;46 Suppl 1:S2-70. doi: 10.1016/j.fct.2008.02.008. Epub 2008 Feb 13. Food Chem Toxicol. 2008. PMID: 18328408 Review.
Cited by
-
A novel ultrasonic method for evaluation of blood clotting parameters.J Med Ultrason (2001). 2018 Oct;45(4):545-553. doi: 10.1007/s10396-018-0874-1. Epub 2018 Mar 13. J Med Ultrason (2001). 2018. PMID: 29536280
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous