Multicenter Study
. 2010 Apr;51(4):842-9.
doi: 10.1016/j.jvs.2009.10.104. Epub 2010 Jan 4.

Robot-assisted laparoscopic repair of renal artery aneurysms

Affiliations
Free article
Multicenter Study

Robot-assisted laparoscopic repair of renal artery aneurysms

Pier Cristoforo Giulianotti et al. J Vasc Surg. 2010 Apr.
Free article

Abstract

Objective: The aim of this article is to report our experience in the repair of renal artery aneurysms using robot-assisted surgery.

Methods: Between December 2002 and March 2009, five women with a mean age of 63.8 years (range, 57-78 years) underwent robot-assisted laparoscopic repair of renal artery aneurysms by the same surgeon at two different institutions, the Department of General Surgery, Misericordia Hospital, Grosseto, Italy (three patients) and the Division of Minimally Invasive and Robotic Surgery at the University of Illinois, Chicago (two patients). The mean size of the lesions was 19.4 mm (range, 9-28 mm). Four of the lesions were complex aneurysms involving the renal artery bifurcation. Two patients were symptomatic and three had hypertension. In situ repair by aneurysmectomy was performed in all cases, followed by revascularization. In complex aneurysms, an autologous saphenous vein graft was used for the reconstruction.

Results: The mean operative time was 288 minutes (range, 170-360 min) and the estimated surgical blood loss was 100 ml (range, 50-300 ml). Warm ischemia time was 10 minutes in the patient treated by aneurysmectomy, followed by direct reconstruction. The average warm ischemia time was 38.5 minutes (range, 20-60 min) for patients treated with saphenous vein graft interposition. The mean time to resume a regular diet was 1.6 days (range, 1-2 days). The mean postoperative length of hospital stay was 5.6 days (range, 3-7 days). No postoperative morbidity was noted. The mean follow-up time for the entire series was 28 months (range, 6-48 months). Color Doppler ultrasonography examination showed patency in all reconstructed vessels. One patient had stenosis of one of the reconstructed branches, which was treated with percutaneous angioplasty.

Conclusions: Robot-assisted laparoscopic repair of renal artery aneurysms is feasible, safe and effective. The technical advantages of the robotic system allows for microvascular reconstruction to be performed using a minimally invasive approach, even in complex cases. This approach may also allow for improved postoperative recovery and reduce the morbidity correlated with open repair of renal artery aneurysms. Although more experience and technical refinements are necessary, robot-assisted laparoscopic repair of renal artery aneurysms represents a valid alternative to open surgery.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms