. 2010 Jun;12(6):798-804.
doi: 10.1093/europace/eup410. Epub 2010 Jan 3.

Changes in P-wave area and P-wave duration after circumferential pulmonary vein isolation

Affiliations

Changes in P-wave area and P-wave duration after circumferential pulmonary vein isolation

Katarina Van Beeumen et al. Europace. 2010 Jun.

Abstract

Aims: The effect of circumferential pulmonary vein isolation (CPVI) on P-wave characteristics is not clear. We used the signal-averaged (SA) electrocardiogram (ECG) and the ECG derived vector cardiogram (dVCG) to study the influence of CPVI on P-wave duration (PWD) and P-wave area (PWA) and studied whether changes were associated with successful outcome after initial CPVI.

Methods and results: Thirty-nine patients (56 +/- 10 years, 72% males) underwent CPVI for paroxysmal or persistent atrial fibrillation (AF). For each patient, an ECG recording was taken at the start and end of the ablation procedure. dVCG was derived using the inverse Dower transform. PWD was defined by manual annotation of earliest onset and latest offset of the SA-P-wave. PWA was calculated as the area under the SA-ECG curve averaged for the 12 ECG leads (PWA-ECG) and SA-dVCG curve (PWA-dVCG). Successful outcome after CPVI was defined as freedom from symptomatic and asymptomatic AF at the end of follow-up (11 +/- 5 months). Average PWD decreased from 132 +/- 14 to 126 +/- 16 ms (P < 0.01). PWA-ECG and PWA-dVCG decreased markedly from 4.64 +/- 1.40 to 3.65 +/- 1.61 mVms (P < 0.001) and from 4.27 +/- 1.66 to 2.48 +/- 1.59 mVms (P < 0.001). Parameters of PWA were not different between successes (n = 31) and failures (n = 8). In contrast, PWD after ablation was significantly shorter in patients with successful outcome (123 +/- 16 vs. 135 +/- 11 ms, P < 0.05).

Conclusion: (i) CPVI results in a modest but significant shortening in PWD and a marked decrease in PWA. (ii) PWD was significantly shorter in cases of successful outcome after CPVI.

PubMed Disclaimer

Comment in

  • A new use for an old technique?
    Stafford PJ. Stafford PJ. Europace. 2010 Jun;12(6):768-9. doi: 10.1093/europace/euq057. Epub 2010 Mar 16. Europace. 2010. PMID: 20233760 No abstract available.