Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association
- PMID: 20048212
- DOI: 10.1161/CIRCULATIONAHA.109.192665
Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association
Abstract
Despite improvements in cardiovascular implantable electronic device (CIED) design, application of timely infection control practices, and administration of antibiotic prophylaxis at the time of device placement, CIED infections continue to occur and can be life-threatening. This has prompted the study of all aspects of CIED infections. Recognizing the recent advances in our understanding of the epidemiology, risk factors, microbiology, management, and prevention of CIED infections, the American Heart Association commissioned this scientific statement to educate clinicians about CIED infections, provide explicit recommendations for the care of patients with suspected or established CIED infections, and highlight areas of needed research.
Republished in
-
A summary of the update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association.J Am Dent Assoc. 2011 Feb;142(2):159-65. doi: 10.14219/jada.archive.2011.0058. J Am Dent Assoc. 2011. PMID: 21282681
Similar articles
-
Cardiovascular implantable electronic device infection in patients with Staphylococcus aureus bacteremia.Pacing Clin Electrophysiol. 2010 Apr;33(4):407-13. doi: 10.1111/j.1540-8159.2009.02565.x. Epub 2009 Sep 30. Pacing Clin Electrophysiol. 2010. PMID: 19793360
-
Nonstaphylococcal infections of cardiac implantable electronic devices.Circulation. 2010 May 18;121(19):2085-91. doi: 10.1161/CIRCULATIONAHA.110.936708. Epub 2010 May 3. Circulation. 2010. PMID: 20439783
-
Cardiovascular implantable electronic device associated infections.Infect Dis Clin North Am. 2012 Mar;26(1):57-76. doi: 10.1016/j.idc.2011.09.001. Infect Dis Clin North Am. 2012. PMID: 22284376 Review.
-
Timing of the most recent device procedure influences the clinical outcome of lead-associated endocarditis results of the MEDIC (Multicenter Electrophysiologic Device Infection Cohort).J Am Coll Cardiol. 2012 Feb 14;59(7):681-7. doi: 10.1016/j.jacc.2011.11.011. J Am Coll Cardiol. 2012. PMID: 22322085
-
Contemporary management of cardiovascular implantable electronic device infections.Expert Rev Anti Infect Ther. 2010 Jul;8(7):831-9. doi: 10.1586/eri.10.54. Expert Rev Anti Infect Ther. 2010. PMID: 20586567 Review.
Cited by
-
Micafungin for Candida albicans pacemaker-associated endocarditis: a case report and review of the literature.Mycopathologia. 2013 Feb;175(1-2):129-34. doi: 10.1007/s11046-012-9591-2. Epub 2012 Oct 17. Mycopathologia. 2013. PMID: 23073824 Review.
-
Forty-Year Trends in Cardiac Implantable Electronic Device Infective Endocarditis.Open Forum Infect Dis. 2022 Oct 14;9(11):ofac547. doi: 10.1093/ofid/ofac547. eCollection 2022 Nov. Open Forum Infect Dis. 2022. PMID: 36381626 Free PMC article.
-
Daptomycin and tigecycline have broader effective dose ranges than vancomycin as prophylaxis against a Staphylococcus aureus surgical implant infection in mice.Antimicrob Agents Chemother. 2012 May;56(5):2590-7. doi: 10.1128/AAC.06291-11. Epub 2012 Feb 27. Antimicrob Agents Chemother. 2012. PMID: 22371896 Free PMC article.
-
A Ghost Left Behind After Transvenous Lead Extraction: A Finding to be Feared.Am J Case Rep. 2020 Jul 27;21:e924243. doi: 10.12659/AJCR.924243. Am J Case Rep. 2020. PMID: 32713936 Free PMC article.
-
Inadvertent Intraoperative Defibrillation Secondary to Electrocautery Grounding Pad Placement.Cureus. 2022 Sep 21;14(9):e29391. doi: 10.7759/cureus.29391. eCollection 2022 Sep. Cureus. 2022. PMID: 36304382 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical