Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 May;31(5):874-9.
doi: 10.3174/ajnr.A1976. Epub 2010 Jan 6.

Assessment of intracranial arterial stenosis with multidetector row CT angiography: a postprocessing techniques comparison

Affiliations
Comparative Study

Assessment of intracranial arterial stenosis with multidetector row CT angiography: a postprocessing techniques comparison

L Saba et al. AJNR Am J Neuroradiol. 2010 May.

Abstract

Background and purpose: It was demonstrated the some patients with stroke have intracranial stenosis of 50% or greater and the identification of intracranial arterial stenosis is extremely important in order to plan a correct therapeutical approach. The aim of this study was to assess the image quality and intertechnique agreement of various postprocessing methods in the detection of intracranial arterial stenosis.

Material and methods: Eighty-five patients who were studied by using a multidetector row CT scanner were retrospectively analyzed. A total of 2040 segments were examined in the 85 subjects. Intracranial vasculature was assessed by using MPR, CPR, MIP, and VR techniques. Two radiologists reviewed the CT images independently. Cohen weighted kappa statistic was applied to calculate interobserver agreement and for image accuracy for each reconstruction method. Sensitivity, specificity, PPV, and NPV were also calculated by using the consensus read as the reference.

Results: Two hundred fifteen (10.5%) stenosed artery segments were identified by the observers in consensus. The best intermethod kappa values between observers 1 and 2 were obtained by VR and MIP (kappa values of 0.878 and 0.861, respectively), whereas MPR provided the lowest value (kappa value of 0.282). VR showed a sensitivity for detecting stenosed segments of 88.8% and 91.6% for observers 1 and 2, respectively. The highest positive predictive value was also obtained by VR at 95% and 99% for observers 1 and 2, respectively. Image accuracy obtained by using VR was the highest among all reconstruction methods in both observers (185/255 and 177/255 for observers 1 and 2, respectively).

Conclusions: The results of our study suggest that VR and MIP techniques provide the best interobserver and intertechnique concordance in the analysis of intravascular cranial stenosis.

PubMed Disclaimer

Figures

Fig 1.
Fig 1.
Sixty-three-year-old female patient: postprocessed VR (A), MIP (B), corona MPR (C), and CPR images (D, E).

Similar articles

Cited by

References

    1. Gibbs RGJ, Todd JC, Irvine C, et al. . Relationship between the regional and national incidence of transient ischaemic attack and stroke and performance of carotid endarterectomy. Eur J Vasc Surg 1998;16:47–52 - PubMed
    1. Murray CJ, Lopez AD. Morality by cause for eight regions of the world: global burden of disease study. Lancet 1997;349:1269–76 - PubMed
    1. Goessens BMB, Visseren FLJ, Kappelle LJ, et al. . Asymptomatic carotid artery stenosis and the risk of new vascular events in patients with manifest arterial disease. Stroke 2007;38:1470–75 - PubMed
    1. Lutsep HL, Clark WM. Association of intracranial stenosis with cortical symptoms or signs. Neurology 2000;55:716–18 - PubMed
    1. Boll DT, Lewin JS, Fleiter TR, et al. . Multidetector CT angiography of arterial inflow and runoff in the lower extremities: a challenge in data acquisition and evaluation. J Endovasc Ther 2004;11:144–51 - PubMed