Atrial activation time and pattern of linear triple-site vs. single-site atrial pacing after cardioversion in patients with atrial fibrillation
- PMID: 20056596
- DOI: 10.1093/europace/eup407
Atrial activation time and pattern of linear triple-site vs. single-site atrial pacing after cardioversion in patients with atrial fibrillation
Abstract
Aims: Multisite atrial pacing has been suggested to be effective in suppressing atrial fibrillation (AF), however, the effect of linear triple-site atrial pacing (LTSP) in humans has not been evaluated. We compared the effects of LTSP to single-site atrial pacing (SSP) on the atrial activation and wavefront propagation pattern in patients with persistent AF.
Methods and results: In 10 patients with persistent AF, the effects of LTSP and SSP were evaluated by left atrial (LA) endocardial non-contact multielectrode array mapping and multipolar catheters. LTSP and SSP were delivered from the high right atrium (HRA), the distal coronary sinus (CS), and within the LA at the site showing maximal overlay of low-voltage zones during sinus rhythm and pacing at HRA and CS. Atrial activation time and pattern, P wave duration, and the prevention of AF induced by burst pacing were assessed with these pacing interventions. Compared with SSP, LTSP at the HRA, CS, and LA shortened atrial activation times (183 +/- 24 vs. 174 +/- 24 ms, 186 +/- 29 vs. 166 +/- 28 ms, and 171 +/- 40 vs. 163 +/- 39 ms; P < 0.05, respectively). P wave duration was shorter with LTSP than SSP at all three sites (141.7 +/- 35.1 vs. 146.9 +/- 38.5 ms, 138.1 +/- 34.6 vs. 145.7 +/- 33.7 ms, and 142.7 +/- 33.4 vs. 151.3 +/- 35.1 ms; P < 0.05, respectively). LTSP initially depolarized a larger area than SSP, and produced more uniform and planar wavefront propagation. LTSP prevented the burst-induction of AF during LA pacing in 3 of 10 patients, while SSP was never successful.
Conclusion: In patients with persistent AF, LTSP provided more rapid and uniform activation of the atria compared with SSP, which was associated with prevention of burst-induction of AF in some patients. Further study is required to determine whether LTSP can modify the substrate of chronic AF, leading to frank AF suppression.
Comment in
-
Can linear triple-site atrial pacing reinforce the electrical treatment of atrial fibrillation?Europace. 2010 Apr;12(4):458-9. doi: 10.1093/europace/euq002. Epub 2010 Jan 29. Europace. 2010. PMID: 20118490 No abstract available.
Similar articles
-
A novel method of multisite atrial pacing, incorporating Bachmann's bundle area and coronary sinus ostium, for electrical atrial resynchronization in patients with recurrent atrial fibrillation.Europace. 2007 Sep;9(9):805-11. doi: 10.1093/europace/eum152. Epub 2007 Aug 1. Europace. 2007. PMID: 17670780
-
Electrophysiology of atrial fibrillation and its prevention by coronary sinus pacing.Semin Interv Cardiol. 1997 Dec;2(4):227-32. Semin Interv Cardiol. 1997. PMID: 9704357 Review.
-
Electrophysiological determinants of atrial fibrillation in sinus node dysfunction despite atrial pacing.Europace. 2000 Oct;2(4):304-11. doi: 10.1053/eupc.2000.0118. Europace. 2000. PMID: 11194597 Clinical Trial.
-
Effects of acute autonomic modulation on atrial conduction delay and local electrograms duration in paroxysmal atrial fibrillation.Int J Cardiol. 2011 Jun 16;149(3):290-5. doi: 10.1016/j.ijcard.2010.02.006. Epub 2010 Mar 17. Int J Cardiol. 2011. PMID: 20299115
-
Hybrid therapy of atrial fibrillation.Ital Heart J. 2002 Oct;3(10):571-8. Ital Heart J. 2002. PMID: 12478814 Review.
Cited by
-
Catheter Ablation of Long-standing Persistent Atrial Fibrillation: a Reckless Challenge or a Way to Real Cure?Korean Circ J. 2019 Feb;49(2):134-145. doi: 10.4070/kcj.2018.0418. Korean Circ J. 2019. PMID: 30693681 Free PMC article. Review.
-
Left atrial dyssynchrony time measured by tissue Doppler imaging to predict atrial fibrillation recurrences after pulmonary vein isolation.Anatol J Cardiol. 2015 Feb;15(2):115-22. doi: 10.5152/akd.2014.5217. Epub 2014 Jun 3. Anatol J Cardiol. 2015. PMID: 25252295 Free PMC article.
-
Predictive value of total atrial conduction time measured with tissue Doppler imaging for postoperative atrial fibrillation after coronary artery bypass surgery.J Interv Card Electrophysiol. 2013 Jun;37(1):27-33. doi: 10.1007/s10840-012-9756-4. Epub 2012 Dec 13. J Interv Card Electrophysiol. 2013. PMID: 23239219 Clinical Trial.
-
Personalized computational modeling of left atrial geometry and transmural myofiber architecture.Med Image Anal. 2018 Jul;47:180-190. doi: 10.1016/j.media.2018.04.001. Epub 2018 Apr 5. Med Image Anal. 2018. PMID: 29753182 Free PMC article.
-
Elimination Of Triggers Without An Additional Substrate Modification Is Not Sufficient In Patients With Persistent Atrial Fibrillation.J Atr Fibrillation. 2015 Feb 28;7(5):1207. doi: 10.4022/jafib.1207. eCollection 2015 Feb-Mar. J Atr Fibrillation. 2015. PMID: 27957155 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical