Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Jan-Feb;30(1):72-9.
doi: 10.3747/pdi.2008.00243.

Comparison of glycated albumin and hemoglobin A1c concentrations in diabetic subjects on peritoneal and hemodialysis

Affiliations
Comparative Study

Comparison of glycated albumin and hemoglobin A1c concentrations in diabetic subjects on peritoneal and hemodialysis

Barry I Freedman et al. Perit Dial Int. 2010 Jan-Feb.

Abstract

Background: Relative to hemoglobin A(1c) (HbA(1c)), percentage of glycated albumin (GA%) more accurately reflects recent glycemic control in diabetic hemodialysis (HD) patients.

Methods: To determine the accuracy of glycemic assays in a larger sample including patients on peritoneal dialysis (PD), HbA(1c) and GA% were measured in 519 diabetic subjects: 55 on PD, 415 on HD, and 49 non-nephropathy controls.

Results: Mean +/- SD serum glucose levels were higher in HD and PD patients relative to non-nephropathy controls (HD 169.7 +/- 62 mg/dL, PD 168.6 +/- 66 mg/dL, controls 146.1 +/- 66 mg/dL; p = 0.03 HD vs controls, p = 0.13 PD vs controls). GA% was also higher in HD and PD patients (HD 20.6% +/- 8.0%, PD 19.0% +/- 5.7%, controls 15.7% +/- 7.7%; p < 0.02 HD vs controls and PD vs controls). HbA(1c) was paradoxically lower in dialysis patients (HD 6.78% +/- 1.6%, PD 6.87% +/- 1.4%, controls 7.3% +/- 1.4%; p = 0.03 HD vs controls, p = 0.12 PD vs controls). The serum glucose/HbA(1c) ratio differed significantly between dialysis patients and controls (p < 0.0001 HD vs controls, p = 0.002 PD vs controls), while serum glucose/GA% ratio was similar across groups (p = 0.96 HD vs controls, p = 0.64 PD vs controls). In best-fit multivariate models with HbA(1c) or GA% as outcome variable, dialysis status was a significant predictor of HbA(1c) but not GA%.

Conclusions: The relationship between HbA(1c) and GA% differs in diabetic patients with end-stage renal disease who perform either PD or HD compared to those without nephropathy. HbA(1c) significantly underestimates glycemic control in peritoneal and hemodialysis patients relative to GA%.

PubMed Disclaimer

Publication types

LinkOut - more resources