Response of the end-plates to compression of the spine
- PMID: 20058443
- DOI: 10.1007/BF00301050
Response of the end-plates to compression of the spine
Abstract
The instantaneous displacement and creep of the caudal end-plate were measured during compression of six segments of cadaveric lumbar spine. Each segment consisted of a disc attached to the two adjacent vertebrae. It was subjected to an applied load of 1.6 kN which was supposed to be within the normal physiological range. End-plate displacement was measured using a displacement transducer. When the load was applied there was an almost instantaneous displacement of the end-plate of 0.14 +/- 0.04 mm (mean +/- standard deviation). The creep displacement in the specimens which remained undamaged was very small (0.023 +/- 0.006 mm) and associated with a retardation time of 1.9 +/- 1.1 s, i.e. the endplate displacement in these specimens reached an equilibrium value within a few minutes. Appreciable endplate displacement (exceeding 4 mm) was associated with damage which included fracture of the trabecular bone. In the damaged specimen, the end-plate continued to displace under a constant load. This result suggests that sustained compression could aggravate mechanical damage to the vertebra and end-plate in vivo.
Similar articles
-
End-plate displacement during compression of lumbar vertebra-disc-vertebra segments and the mechanism of failure.Spine (Phila Pa 1976). 1993 Jan;18(1):128-35. doi: 10.1097/00007632-199301000-00019. Spine (Phila Pa 1976). 1993. PMID: 8434313
-
Intervertebral disc decompression following endplate damage: implications for disc degeneration depend on spinal level and age.Spine (Phila Pa 1976). 2013 Aug 1;38(17):1473-81. doi: 10.1097/BRS.0b013e318290f3cc. Spine (Phila Pa 1976). 2013. PMID: 23486408
-
Intervertebral disc degeneration can lead to "stress-shielding" of the anterior vertebral body: a cause of osteoporotic vertebral fracture?Spine (Phila Pa 1976). 2004 Apr 1;29(7):774-82. doi: 10.1097/01.brs.0000119401.23006.d2. Spine (Phila Pa 1976). 2004. PMID: 15087801
-
The effect of nucleotomy on lumbar spine mechanics in compression and shear loading.Spine (Phila Pa 1976). 2001 Oct 1;26(19):2080-9. doi: 10.1097/00007632-200110010-00007. Spine (Phila Pa 1976). 2001. PMID: 11698883
-
Recent advances in analytical modeling of lumbar disc degeneration.Spine (Phila Pa 1976). 2004 Dec 1;29(23):2733-41. doi: 10.1097/01.brs.0000146471.59052.e6. Spine (Phila Pa 1976). 2004. PMID: 15564922 Review.
Cited by
-
Spine biomechanical testing methodologies: The controversy of consensus vs scientific evidence.JOR Spine. 2021 Jan 5;4(1):e1138. doi: 10.1002/jsp2.1138. eCollection 2021 Mar. JOR Spine. 2021. PMID: 33778410 Free PMC article. Review.